35
Side view on the opened
HV Transformer
AC Selector
Remove the upper lid first. On the right side of the PA, next to the HV transformer there are two PCBs
mounted. On the left upper side of the front (Switch-ON) board connector J6 is located.
Use flat screwdriver or finger and press carefully
the white stick to release contact and move upper
end of the white jumper to the proper position, if
necessary
.
Jumper must be connected between bottom contact
and one of remaining contacts. AC voltage is
marked next to every contact.
AC selector range can be changed in the production according to the specific conditions in
individual countries. Default settings is 220V – 240V / 50 Hz for EU market and 230V – 250V /
60Hz for US market. If you need different settings in the range of 200 – 260V, this should be
specified in the order!
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.