CAUTION
Be sure that your power system is correctly wired and properly rated! To use adequately sized and connected
grounding system is also very important.
4.5.
Cooling
CAUTION
The amplifier must be installed in such a way that free flow of hot air from the amplifier is allowed. Do not
obstruct air intake and exhaust areas of the PA.
Installed axial fan provides adequate cooling of the amplifier, even during long time operation. It is automatically
activated when PA is switching ON. There are two modes of fan speed selectable. In the normal mode fan speed
is gradually rising with increasing temperature. In the contest mode the fan is switched at a constant high speed.
Fan inside the power supply starts to operate depending on the current drawn by the MOSFET.
When the amplifier reaches inside temperature of 75 deg. Celsius, warning appears and fault LED starts
blinking. At 80 degrees transmitting will be automatically blocked, fault LED will light.