parameter
model
STC10-
LED-V2.0
rated
charge
current
10A
system
voltage
Max
.
pv
power
12
Vsystem
:170
W 24V system
:340
W
Max
.
load
power
12
V system
:
Max.
30W. 24V
system
:
Max
.60
W
Rated
load
current
2
A
Max
.
LED series
: 12
V system
: 14
series
. 24
V system
: 14
series
.
over
load,short current protect
yes
no
-
load
current
≤6 mA
over
-
voltage protection
16V(12V), 32V/24V;
work
temperature
: -35℃至+60℃
boost
voltage
14.4
V
(12
V
), 28.8/(24
V
)
Equalization voltage
14.6
V
(12
V
), 29.2
V
/(24
V
)
Float
voltage
13.8V(12V), 27.6V/(24V)
recharge
voltage
13.2V(12V); 26.4/(24V);
Temperature
compensation
-5mv/℃/2V
low
-
voltage warning
12V(12V); 24V/(24V)
Low-voltage disconnect
11V(12V); 22/24V;(可设置)
load
reconnect
voltage
12.6V(12V), 25.2/(24V)
over
-
heat
protection
70℃
dimension
104*28*85
mm
weight
400
g
IP
Ip
68
remote
controller
Infrared remote controller (optional)
12
V
/24
V
Automatic detection
E1 -battery over discharge and voltage is lower over discharge point
E2 -battery over discharge and voltage is lower over discharge point without getting to back point
E3 -load
over
load
E4 -load short circuit
E5 -open load
"."-
The
radix
point
of
LED
1
lighting
up
indicates
that
load
is
open
.
oppositely,load is closed
The reference of LED for error code is shown in the table