OLYS STC-LED-V2.0 Series User Manual Download Page 4

parameter

model

                                         STC10-

LED-V2.0

rated

 

charge

 

current

                        10A

system

 

voltage

                               

Max

.

pv

 

power

                                  12

Vsystem

:170

W        24V system

:340

W

  

Max

load

 

power

                              12

V system

Max.

30W. 24V 

system

Max

.60

W

      

Rated

 

load

 

current

                           2

A

Max

.

LED series

:                              12

V system

: 14 

series

.         24

V system

: 14

series

.                         

over

 

load,short current protect

            

yes

no

-

load

 

current

                              ≤6 mA

over

-

voltage protection

                    16V(12V), 32V/24V;

work

 

temperature

:                           -35℃至+60℃ 

boost

 

voltage

                                14.4

V

(12

V

),  28.8/(24

V

)

Equalization voltage

                        14.6

V

(12

V

), 29.2

V

/(24

V

)

Float

 

voltage

                                13.8V(12V),  27.6V/(24V)

recharge

 

voltage

                            13.2V(12V); 26.4/(24V);

Temperature

 

compensation

                   -5mv/℃/2V

low

-

voltage warning

                         12V(12V);    24V/(24V) 

Low-voltage disconnect

                     11V(12V);   22/24V;(可设置) 

load

 

reconnect

 

voltage

                      12.6V(12V),   25.2/(24V)

over

-

heat

 

protection

                        70℃

dimension

                                     104*28*85

mm

weight

                                         400

g

IP

                                             

Ip

68

remote

 

controller

                            

Infrared remote controller (optional)

                                   

12

V

/24

V

 

Automatic detection

  

E1 -battery over discharge and voltage is lower over discharge point

E2 -battery over discharge and voltage is lower over discharge point without getting to back point                                                                                                                   

E3 -load

 

over

 

load

E4 -load short circuit

E5 -open load

"."- 

The

 

radix

 

point

 

of

 

LED

lighting

 

up

 

indicates

 

that

 

load

 

is

 

open

oppositely,load is closed

The reference of LED for error code is shown in the table