Parameter

Model                                                MPPT3010         

rated charging current                    10A

Max PV voltage                                30V

Max PV power                                  130W        

rated load current                            10A           

system voltage                                 12V                         

Battery type                                      Lead-acid(AGM,GEL,Sealed)

Over-voltage cut off load               16V    

Hight -voltage protection               15.5V  

Over-voltage recovery voltage     13.7V

Equalizing charge                           14.5V

Boost charge                                   14.4V

Float charge                                    13.8V 

Boost charge recovery                    13.2V

load reconnect voltage                   12.5V

Low voltage alarm                           11.5V

low-voltage protection                    11V

Working temperature                      -20

--50

Dimension                                        135*105*37mm

Weight                                               200g                             

  Overheating

 

protection

 

The internal temperature of the controller is more than 80 

, the controller stops charging, and when the 

temperature drops to 60 

℃,

 resume charging. If the overheating protection is repeated three times, the

charging will be stopped completely. If you need to recharge, you must reset manually or the next day 

before you can recharge.

  Reverse protection

 

Polar panel reverse connection

: 

no charging, the controller unaffected.

Battery reverse connection

:   

the fuse burns out and the controller unaffected.

Load reversal

: 

load damage, controller may be damage

 

PV

 

overvoltage, overpower protection

 

PV overvoltage: >30V,stop charging

PV overpower:   >130W,stop charging,Re-tested every 10 minutes

3.

 

load current>20A

,

The controller determines the load is short-circuited and turns off the load output directly.

                   

4.

 

If the load protection occurs, turn on the load switch again and again after 120s, if the overload phenomenon 

occurs more than 3 times repeatedly, turn off the load completely. Reset the machine before it can be reopened.

Warning

: the load should not be short-circuited directly, which may cause damage to the controller

The manufacturer shall not be liable for damages, especially on the battery, caused by use other than as intended or as 

mentioned in this manual or if the recommendations of the battery manufacturer are neglected. The manufacturer shal

l not be liable if there has been service or repair carried out by any unauthorized person, unusual use, wrong installation,

 or bad system design