background image

PV8355F4E007

I

Optical Measuring Instrument 

Accessory 

Instruction Manual 

USPM-RU-W series 

USPM-TU 

Before use 

Thank you for purchasing our transmit unit. In order to use this product safely and to 
maximize the benefits from doing so, be sure to read this instruction manual completely 
before use. This manual describes only the contents of the transmit unit, thus read this 
manual together with the 

instruction manual for the NIR Micro-spectrophotometer 

USPM-W-B

 in the attached sheet. 

Please keep this manual close at hand when using the product, and store it carefully for 
future reference after you have read it. 
This instruction manual contains a warranty card (on page 5). Confirm and fill in the 
necessary items and store the warranty card in a safe place.

 

Summary of Contents for USPM-RU-W Series

Page 1: ...letely before use This manual describes only the contents of the transmit unit thus read this manual together with the instruction manual for the NIR Micro spectrophotometer USPM W B in the attached s...

Page 2: ...rmation of Packaged Products 7 2 Part Names and Functions Specifications 9 3 Equipment Installation and Connection 12 4 Usage 14 5 Notes on Storing 23 6 If Abnormality Occurs 23 7 Conforming to Laws a...

Page 3: ...or our service department for replacement or other inquiries Mark Description Do not touch because the surface is hot Otherwise you can get burned Indicates a warning or caution covering a wide range...

Page 4: ...this product are as follows Indicates the proper upper direction of the packaged cargo Indicates that the packaged cargo must not be exposed to rain Indicates that packaged cargo must be carefully ha...

Page 5: ...ated equipment simultaneously used in a location where you can refer to them immediately Contact the retailer or our service department if you have any questions regarding the contents of this instruc...

Page 6: ...on manual of the NIR Micro spectrophotometer USPM W B Observe the cautions below when handling this product Notice that each chapter also describes each caution Gently operate each adjustment knob Gen...

Page 7: ...during correct usage compliant with the manual and warning labels during the warranty period 2 We do not warrant any failure due to other causes e g peripheral device s or the environment at the insta...

Page 8: ...e accuracy of the contents of this document if you discover any unclear point or mistakes omissions please consult with the contact point listed in the attached sheet Regardless of the preceding provi...

Page 9: ...set and supplied accessories are completely received and check whether products are missing or damaged Contact the retailer or our service department immediately without using the products if parts a...

Page 10: ...or unit for transmittance and tilt stage Name Quantity Remarks 3 collimator unit for transmittance 1 1 4 Tilt stage 1 1 5 Lamp housing 1 6 Lamp cable 1 7 Halogen lamp exclusively used for this device...

Page 11: ...llimator unit for transmittance This consists of a light source unit used for optional transmission measurement and 45 degree measurement Fix the lamp housing using the two fixing knobs For more detai...

Page 12: ...djustment knob 4 Polarization unit This unit adjusts the polarization state to P S or random polarization using a polarization switching knob Polarization switching knob Tilt adjustment knob Adjusts t...

Page 13: ...s Specifications Name Transmittance Measurement Unit Type USPM TU Wavelength range 380 to 1050 nm Wavelength resolution Approx 5 nm Wavelength display resolution 1 nm Repeatability 3 0 3 or less 430 1...

Page 14: ...levers 4 Insert the lamp housing into the former position Adjust it so that the lamp connector faces the right of the device Check the encircled part and then check the screw hole position and the la...

Page 15: ...erformance cannot be secured when the wall outlet is not grounded 5 Protection key Any USB port on the computer The power cord may melt and short circuit if it makes contact with the lamp housing Keep...

Page 16: ...Option Customers who purchase a polarization unit See 4 5 Polarization state settings 5 Set a work setting file See 4 6 Setting a work setting file For reference setting select FIXED and enter 100 6...

Page 17: ...double click the shortcut icon on the desktop and start the program 4 3 Revolver settings 1 Set a revolver A revolver is adjusted to the through position in which an objective lens is not installed wh...

Page 18: ...tion you want to measure The polarization direction faces the stage surface Refer to the figure below Gently operate the optical path switching knob used for the optical switching unit Applying excess...

Page 19: ...setting file For more details see 6 2 Work setting in the Software Instruction Manual USPM SA 1 Select Set Work from the file menu A WORK setting window appears 2 Set the reference 1 Click and fix FI...

Page 20: ...t position of the FOCUS window 3 Adjust the outgoing beam s tilt of reference standard light flux For the tilt adjustment of a reference standard light flux observe the FOCUS window of the software an...

Page 21: ...on measurement Adjust the numeric value Y displayed in the upper left position of the CT window to Y 0 1 4 8 Adjusting the sampling time Adjust the sampling time so that the spectral light intensity...

Page 22: ...E in the operation panel 4 11 Setting a measurement sample 1 Install the measurement sample on the upper surface of the tilt stage The measurement sample is placed at the holed point in the center of...

Page 23: ...the measurement result are displayed on the TEXT window 3 DIAGRAM window The measurement result of the chromaticity diagram is displayed on the DIAGRAM window XY and Lab chromaticity diagrams can be d...

Page 24: ...line indicates the lower limit of the spectroscopic quantity defined in the system configuration window 6 LUMINANCE TEXT window Each spectral light intensity of a background reference and measurement...

Page 25: ...urs Make confirmation through the combined use of 6 If Abnormality Occurs in the instruction manual for NIR Micro spectrophotometer USPM W B 7 Conforming to Laws and Regulations See 7 Conforming to La...

Page 26: ...is adjusted to the through position in which an objective lens is not installed 4 Install a BK7 reference sample in the tilt stage 5 Adjust the tilt of two axes to the optical axis using the tilt sta...

Page 27: ...in the instruction manual for the NIR Micro spectrophotometer USPM W B and remove the work installing plate 2 Adjust the scale of the shift stage to point 0 3 In the figure below the transmission wind...

Page 28: ...l rights reserved The contents of this manual shall not be reproduced or distributed in part or in whole without Olympus s consent The company and product names described in this manual may be tradema...

Page 29: ...A CO LTD 8F Olympus Tower 446 Bongeunsa ro Gangnam gu Seoul Korea 135 509 Tel 82 2 6255 3458 OLYMPUS THAILAND CO LTD 159 Serm mit Tower 9th floor unit 906 910 Sukhumvit21 road North Klongtoey Wattana...