Summary of Contents for SZX2 Series

Page 1: ...obtain optimum performance and familiarize yourself fully with the use of this equip ment we recommend that you study this manual thoroughly before operating the equipment Retain this instruction manual in an easily accessible place near the work desk for future reference A X 7 5 0 7 SZX2 ILLC16 ILLC10 SZX2 COAXIAL VERTICAL ILLUMINATORS ...

Page 2: ......

Page 3: ...TS IMPORTANT Be sure to read this chapter for safe use of the equipment 1 2 1 USABLE OBSERVATION MAGNIFICATIONS 3 2 NOMENCLATURE 4 4 SUMMARY OF OPERATION PROCEDURE 8 3 ASSEMBLY 5 7 5 OPERATION 9 10 6 TROUBLESHOOTING GUIDE 11 12 ...

Page 4: ...ity dust or vibrations 2 Maintenance and Storage 1 To clean the lenses and other glass components simply blow dirty away using a commercially available blower and wipe gently using a piece of cleaning paper or clean gauze If a lens is stained with fingerprints or oil smudges wipe it gauze slightly moistened with commercially available absolute alcohol Since the absolute alcohol is highly flammable...

Page 5: ...d in this instruction manual The following symbols are used to set off text in this instruction manual Indicates that failure to follow the instructions in the warning could result in bodily harm to the user and or damage to equipment including objects in the vicinity of the equipment Indicates that failure to follow the instructions could result in damage to equipment Indicates commentary for eas...

Page 6: ...9 Zoom Microscope Body SZX ZB7 Objective Total Mag A Zoom Mag B Objective Total Mag A Zoom Mag B Total Mag A Zoom Mag B SDFPLFL0 3X SDFPLAPO0 5XPF SDFLPLAPO0 8X SDFPLAPO1XPF SDFPLAPO1 6XPF SDFPLAPO2XPFC 18X 19X 12X 37 5X 4X 2 5X 1X 2 5X DFPL0 5X 4 DFPL0 75X 4 DFPLAPO1X 4 SZX ACH1X DFPLAPO1 25X SZX ACH1 25X DFPL1 5X 4 DFPL2X 4 15X 14X 12X 15X 12X 12X 56X 96X 2X 1 25X 0 8X 1X 0 63X 0 63X 2 5X 3 2X 1...

Page 7: ...te SZX2 ILLC1 4 Quarter wave plate rotation annulus Branched Flexible Light Guide LG DF Outgoing light guide end This illustration uses the SZX2 ILLC16 The light guide mount of the SZX2 ILLC10 is slightly narrower than that shown here Light guide mount Light guide clamping screws Clamping knob Incident light guide end ...

Page 8: ... vertical illuminator SZX2 ILLC16 ILLC10 is not considered to be an intermediate attachment so it is always possible to mount an intermediate attachment above the SZX2 ILLC16 ILLC10 Be sure to mount the SZX2 ILLC16 ILLC10 directly above the zoom microscope body Allen screwdriver Provided with the zoom microscope body Required Tool Observation tube Intermediate attachment Coaxial vertical illuminat...

Page 9: ...nator can also be mounted in the opposite orientation to that shown in Fig 1 However this orientation is not recommended because it makes observation difficult 3 Tighten the observation tube clamping screw on the microscope body with the Allen screwdriver 4 Mount the observation tube on the coaxial vertical illuminator Fig 2 2 Mounting the Branched Flexible Light Guide Figs 2 3 1 Loosen the clampi...

Page 10: ...n the middle due to a spring Tighten the clamping screws 5 3 Mounting the Quarter Wave Plate Fig 4 1 Loosen the two quarter wave plate clamping knobs 2 Fit the quarter wave plate onto the tip of the objective and secure the clamping knobs The quarter wave plate should be mounted so that the clamping knobs are on the side when seen from the front of the microscope i e so that the module indication ...

Page 11: ... the light source unit and adjust the brightness 4 Adjust the orientation of the quarter wave plate P 9 Observation Procedure 1 Place a specimen on the stage 2 Adjust the brightness to an easy to observe level 3 Turn the quarter wave plate rotation annulus to select an optimum rotation position P 10 4 Observe the specimen with the standard observation procedure Refer to the instruction manuals of ...

Page 12: ...at the clamping knobs are exactly to the side of the microscope when seen from the front i e so that the module indication faces the front Fig 6 2 Adjusting the Brightness Fig 6 Adjustment according to light source bulb voltage Adjust the brightness by turning the light in tensity adjustment knob on the light source unit Adjustment according to iris aperture Adjust brightness by turning the iris a...

Page 13: ... the brightness as described in 2 above B Reflected light polarized observation of liquid crystal etc 1 Perform Cross Nicol observation with the darkest field of view 2 For accurate Cross Nicol adjustment place a flat mirror surfaced speci men on the specimen and make the field of view as dark as possible by turning the quarter wave plate rotation annulus 3 Observe the specimen by rotating it on a...

Page 14: ... bulb of the light source unit is not mounted properly Mount the bulb properly Color reproduction in the photography is poor The brightness control of the power trans former is not set to the maximum posi tion Set the brightness control to the maxi mum position The filters 30 5S LB80 and 30 5 LBD are not used when a daylight type film is in use Mount the filters 30 5S LB80 and 30 5 LBD on the LG P...

Page 15: ......

Page 16: ...AX7507 05 8F Olympus Tower 446 Bongeunsa ro Gangnam gu Seoul Korea 135 509 Biological Industrial Distributed by Shinjuku Monolith 2 3 1 Nishi Shinjuku Shinjuku ku Tokyo 163 0914 Japan Manufactured by ...