 Assembly

The diagram below shows how to assemble the various microscope modules. The numbers in the diagram 
indicate the order of assembly.

Lay out the cables so that they do not hinder the observers.

·

When assembling the microscope, make sure that all parts are free of dust and dirt, and avoid scratching 
any parts or touching the glass surfaces.

·

Some of the modules are very heavy. Be very careful not to drop them.

When transporting the system, remove the SZX2-FOA or SZX2-FOFH from the pillar.

CAUTION

NOTE

TIP

1

2

4

5

5

6

6

3

3

Primary observer
Observation tube

SZX2-TR30

SZX2-TR30PT

SZX2-TTR

SZX2-TTRPT

SZX-BI30

SZX-BI45

Secondary observer
Observation tube

SZX-BI30

SZX-BI45

Focusing assembly

SZX2-FOFH

SZX2-FOA

Microscope body

SZX2-ZB10

SZX-ZB7

Large base

SZX2-STL2

Pillar

Side-by-side 

viewing attachment

SZX-SDO2

Power cord

AC adapter

Mount

Allen wrench (Large)
(Provided with the SZX-SDO2)

Allen wrench
(Provided with the large base)

Allen screwdriver
(Provided with the microscope body)

Required Tools

5  -1  Assembly diagram

Summary of Contents for SZX-SDO2

Page 1: ...f fully with the use of this attachment we recommend you study this manual thoroughly before operating the attachment Retain this instruction manual in an easily accessible place near the work desk for future reference For details of products other than SZX SDO2 see 1 Nomenclature P 3 Side by side viewing attachment FOR SZX10 SZX7 SZX SDO2 Optical Microscope Accessory ...

Page 2: ...ce pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the product is operated in a commercial environment This product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this pro...

Page 3: ...her 9 3 4 Photomicrography cautions 9 4 Specifications 10 5 Assembly 12 5 1 Assembly diagram 12 5 2 Detailed assembly procedure 13 Contents Correct assembly and adjustments are indispensable for the microscope to manifest its full performance If you want to assemble the microscope by yourself see 5 Assembly P 12 first ...

Page 4: ......

Page 5: ...on interferes with the pointer color selector lever when the tube is tilted at the lowest position and the interpupillary distance is minimized Observation tube for the secondary observer Applicable binocular observation tube for SZX10 or SZX7 Eyepiece With built in helicoid Intermediate attachment SZX2 ILLC10 below the SZX SDO2 Note that there may be insufficient ambient light and decentration No...

Page 6: ... make sure to put the dust cover on it 5 This equipment should be disposed of by following the rules and regulations of your national or local government NOTE 2 Maintenance and storage Safety symbols The following symbols are found on the microscope Study the meaning of the symbols and always use the equipment in the safest possible manne Symbol Explanation Before use carefully read the instructio...

Page 7: ...R30 SZX2 TR30PT SZX2 TTR SZX2 TTRPT SZX BI30 SZX BI45 Large base SZX2 STL2 Primary observer side Secondary observer side Focusing assembly SZX2 FOFH SZX2 FOA Observation tube SZX BI30 ZX BI45 SZX microscope body SZX2 ZB10 SZX ZB7 Focusing assembly SZX microscope body Large base Observation tube AC adapter Side by side viewing attachment SZX2 TR30 SZX2 TR30PT SZX2 TTR SZX2 TTRPT SZX BI30 SZX BI45 S...

Page 8: ...light control Pointer color switching lever P 8 Top position Red Middle position Light shielded Bottom position Green Rotation tension adjustment ring Adjust by inserting the Allen wrench in the hole of the ring Right rotation Heavier Left rotation Lighter Rotation tension adjustment ring Coarse focus adjustment knob Full stroke 80 mm Single rotary stroke 36 8 mm Fine focus adjustment knob Full st...

Page 9: ...e large Allen wrench the secondary observer can be positioned on the left side of the microscope In this case however the pointer control lever is located on the rear side interfering with operability In addition the pointer cannot be imaged on the photomicrograph or TV screen of the trinocular observation tube for the main observer The SZX STAD1 or SZH STAD1 stage adapter the SZX STAD2 stage adap...

Page 10: ...TL2 a as shown below In this case the height of the base surface is raised for the same amount as the height of the transmitted light illuminator This makes it necessary to attach the SZX R drop prevention ring optionally available to the pillar of the SZX2 STL2 For reflected light illumination refer to the related instruction manuals TIP b a ...

Page 11: ...tment knobs of the focusing assembly to focus on the specimen Looking into the left eyepiece turn the helicoids e to focus on the specimen Turn the coarse and fine focus adjustment knobs of the microscope to focus on the specimen The pointer and the coarse and fine focus adjustment knobs can be operated only from the primary observer s side They cannot be controlled by the secondary observer 1 TIP...

Page 12: ...the control to the fully counterclockwise position switches it off TIP 1 2 Using the pointer color switching lever b select a color which is clearly distinguishable from the specimen color Top position Red Middle position Light shielded Bottom position Green The main observer can move the pointer to the desired location in the field of view by operating the pointer control lever c on the front of ...

Page 13: ...ate contrast This has the following effects on photographs that are not apparent during visual observation 1 Since the pointer is always overexposed when exposure is correct for the specimen the pointer color will fade to white in color photographs 2 When taking a photograph with a photomicrography system with automatic exposure control the brightness of the pointer will cause the specimen to be u...

Page 14: ...um field of view mm 22 mm dia at primary and secondary observers positions 6 Mounting base Mounted on SZX2 STL2 using SZX2 FOFH or SZX2 FOA Cannot be mounted on other bases 7 Pointer Shape Arrow upward when observed through binocular assembly Colors 3 step switching Top position Red Middle position Light shielded Bottom position Green Movement Joystick Controllable only by primary observer 8 Point...

Page 15: ...cations pillar mounting locations 4 Dimensions 500 W x 350 D x 424 H mm 5 Weight 9 5 kg 20 9 lb Operating environmen Indoor use Altitude Max 2 000 m Ambient temperature 5 C to 40 C 41 F to 104 F Maximum relative humidity 80 for temperatures up to 31 C 88 F decreasing linearly through 70 at 34 C 93 F 60 at 37 C 99 F to 50 at 40 C 104 F Supply voltage fluctuation 10 Pollution degree 2 in accordance ...

Page 16: ... them When transporting the system remove the SZX2 FOA or SZX2 FOFH from the pillar CAUTION NOTE TIP 1 2 4 5 5 6 6 3 3 Primary observer Observation tube SZX2 TR30 SZX2 TR30PT SZX2 TTR SZX2 TTRPT SZX BI30 SZX BI45 Secondary observer Observation tube SZX BI30 SZX BI45 Focusing assembly SZX2 FOFH SZX2 FOA Microscope body SZX2 ZB10 SZX ZB7 Large base SZX2 STL2 Pillar Side by side viewing attachment SZ...

Page 17: ...sembly with both hands insert the pillar c into the mounting hole b Insert gently without applying excessive force After inserting the focusing assembly until it reaches the stop position secure it with the focusing assembly clamping knob a To prevent the microscope body from turning over be sure to mount the focusing assembly so that it is located on the front as shown by in figure below and clam...

Page 18: ... SZX SDO2 side by side viewing attachment on the mount d so that the secondary observer s position is on the right side as shown in figure Insert the 4 clamping screws e provided with the SZX SDO2 attachment into the 4 screw holes and tighten using the Allen wrench 4 mm across flats provided with the SZX SDO2 attachment If the pillar support is installed on the left side of the base mount the atta...

Page 19: ...N 1 2 3 The observation tubes for the primary and secondary observers are both mounted the same way Using the Allen screwdriver fully loosen the observation attachment clamp ing screw a on the secondary observer s observation tube this screw is located on the front and remove the dust cap Align the positioning groove b on the observation tube with the position ing pin c on the side by side viewing...

Page 20: ... cord and AC adapter provided by Olympus If no power cord is provided with the microscope please select the proper power cord by referring to section PROPER SELECTION OF THE POWER SUPPLY CORD at the end of this instruction manual Firmly connect the AC adapter s output plug a to the AC adapter input connector b on the left side panel of the side by side viewing attachment Connect the power cord s c...

Page 21: ...y locally the power supply cord which is approved by one of the agencies mentioned in Table 1 please use replacements approved by any other equivalent and authorized agencies in your country Country Agency Certification mark Country Agency Certification mark Argentina IRAM Italy IMQ Australia SAA Japan JET Austria ÖVE Netherlands KEMA Belgium CEBEC Norway NEMKO Canada CSA Spain AEE Denmark DEMKO S...

Page 22: ...Cables BASEC BASEC HAR 10 10 30 N V KEMA KEMA KEUR HAR 10 30 30 SEMKO AB Svenska Elektriska Materielkontrollanstalter SEMKO HAR 10 10 50 Österreichischer Verband für Elektrotechnik ÖVE ÖVE HAR 30 10 50 Danmarks Elektriske Materialkontroll DEMKO DEMKO HAR 30 10 30 National Standards Authority of Ireland NSAI NSAI HAR 30 30 50 Norges Elektriske Materiellkontroll NEMKO NEMKO HAR 10 10 70 Asociacion E...

Page 23: ......

Page 24: ...Distributed by Manufactured by Shinjuku Monolith 2 3 1 Nishi Shinjuku Shinjuku ku Tokyo 163 0914 Japan www olympus global com AX7748 09 Issued in March 2019 ...

Reviews: