Olympus JetHeat OLY-J5/3 Manual Download Page 2

4. ASSEMBLY (

OLY-J15/3

 ONLY)

1.2.3.  OPERATIONAL PRECAUTIONS

The heater must only be used by people who have read these 

instructions and have been trained in its use.  

DO NOT

 obstruct the air inlet and outlet sections of the heater.

DO NOT

 cover the heater.

DO NOT

 touch the heater casing or grille when first switched    

off, as these will be very hot and will take time to cool.

DO NOT

 get the heater wet or use in areas of high 

condensation.

DO NOT

 allow the power lead to touch hot surfaces.

DO NOT

 connect the heater to a timer device or other

equipment than can automatically switch the heater on or off.

If an extension cable is required it must be of the same cross    

section as the heater cable. It must be as short as possible

and fully unwound.

DO NOT

 connect other appliances to the same mains socket as 

the heater.

1.2.4.  COMMON SENSE PRECAUTIONS

DO NOT

 operate the heater when you are tired or under the 

influence of alcohol, drugs or intoxicating medication. 

DO NOT

 stand on the heater.

DO NOT

 use the heater with wet hands or when there is water   

on the power cord. 

Ensure that the heater is correctly turned off when not in use    

and store in a safe, dry, childproof location. 

DO NOT

 use the heater for anything other than its intended    

purpose. It is designed to provide heat in enclosed areas larger 

than 4m³, such as workshops and other industrial areas. It is    

not suitable for drying clothes or laundry.

Electric fan heaters for industrial applications. 

JetHeat 

Model 

N

umbers:

 

OLY-J5/3 & OLY-J9/3

 feature two heat settings and 

fan only  option. Model No. 

OLY-J15/3

 features three heat 

settings and adjustable thermostat control with fan only option. 

Auto cooling   system to prevent unit from overheating during 

use. A totally dry heat with no condensation, no gas, no fumes, 

no smell. Ideal for workshops and garages. Model No. 

OLY-

J5/3 

OLY-J9/3

 

are 

supplied with three phase power cable 

and plug. Model No. 

OLY-J15-3

 supplied with three phase 

plug (extension lead required).

Model No: . . . . .

 

O L Y - J 5 / 3 . . . O L Y - J 9 / 3 . . . O L Y - J 1 5 / 3

Class:

  . . . . . . . . . . . . IPX4. . . . . . . . .

 

IPX4  . . . . . . . . .

 

IPX4

 

Max. Power:

. . . . . . . .

 

5000W. . . . . . . . 9000W  . . . . . . .

 

15000W

 

Supply:

  . . . . . . . . . 415V-16A. . . . . . 415V-16A . . . . . .

 

415V-32A

 

Heat Settings:

 

.

. .

. 2500/5000W. . .

 

4500/9000W  .

. .

. 5000/10000/15000W

 

S

etting

 Range

 

Thermostat:

. . . . . . .

 

0 - 40ºC. . . . . . . 0 - 40ºC  . . . . . . . . 0 - 40ºC

 

Size (mm):

 

. .

.

. . 315x330x400.

. . .

. . 350x405x460 

. .

. .

 

495x520x860

fig.

fig.

fig.

4.1.  ASSEMBLY OF THE LEGS.

 (See fig.1)

4.1.1.  On either side of the heater body there are two threaded inserts 

(B) for mounting the 'V' shaped leg frames (A). Note that the 

axle hole at the shorter end of the 'V' frames should be 

orientated towards the back of the heater. 

4.1.2.  Take two M8 x 40mm bolts (D) and slide a plain washer (C) onto 

each one. Insert a bolt through each of the mounting holes on  

the leg frame and slide a split washer (E) over each protruding 

bolt. Align the bolts with the two threaded inserts (B) on the  

heater body  and screw them down securely.

4.1.3.  Mount the other 'V' frame to the other side of the heater body in 

the same way.

4.2.  ASSEMBLY OF THE WHEELS.

 (See fig.2)

4.2.1.  Take the axle rod (F) and insert it through the holes in the 'V' 

frames so that the threaded rod ends protrude equally either  

side. Retain the axle rod in this position by inserting a split pin 

(G) through the holes situated just on the inside of each leg  

frame.

Original Language UK English

IMPORTANT!  

This unit is designed to raise the ambient temperature  

of an entire room, the temperature of the air coming out of the    

front of the heater will be warmer than the general temperature  

of the room, but there may not be a significan  increase owing to 

the large volume of air passing over the element. For the same  

reason, the element is hot during operation, but does not glow.   

The room temperature depends on room size, insulation and    

ambient temperature, which will increase as the room warms.

2. INTRODUCTION

3. SPECIFICATION

Olympus OLY-JetHeat | Issue 2) 17/08/16

© Olympus Industrial Appliances UK