background image

8

Notes on conformity and disposal

CE Conformity (Europe)

This product complies with the requirements of Directive 2014/30/EU
concerning electromagnetic compatibility according to Standard
IEC/EN61326-1.

n

Emission: Class B

n

Immunity: Applied to industrial and basic requirements.

WEEE declaration (Europe)

In accordance with the European directive on Waste of
Electrical and Electronic Equipment, this symbol indicates that
the product must not be disposed of as unsorted municipal
waste but should be collected separately. Refer to your local
authority in the EU for return and/or collection systems
available in your country.

RoHS conformity (Europe)

This Olympus Soft Imaging Solutions camera conforms with the
European Union directive on the restriction of the use of certain
hazardous substances in electrical and electronic equipment
2011/65/EU.

8 Notes on conformity and disposal

27

Summary of Contents for DP23

Page 1: ...Instruction Manual DP23 DP28 Microscope Digital Camera OpticalMicroscope Accessory English...

Page 2: ...ing and storage conditions 12 3 System environment 13 3 1Microscope and camera adapter 13 3 2 Recommended computer and monitor configuration 14 3 3 Restrictions onuse 14 4 Assembly 17 4 1Attaching the...

Page 3: ...ructionmanual This instructionmanualapplies to the DP23 and DP28 microscope digitalcameras Informationabout the operationofthe microscope computer or software canbe found inthe instructionmanuals for...

Page 4: ...mera is intended to be used for the acquisitionofdigital images but not for medicaldiagnosticpurposes 1 2 Avoiding personal injury and device damage WARNING Avoiding personal injury Electricshockdue t...

Page 5: ...g Use onlythe supplied USB camera cable Operate the camera onlywiththe supplied USB camera cable Only thenwillthe functionalityofthe camera and compliance withthe EMC basicstandards be ensured Don t t...

Page 6: ...ons see page 12 1 3 Explanation of the symbols used WARNING Indicates a potentially hazardous situation which if not avoided may result in major injury CAUTION Indicates a potentially hazardous situat...

Page 7: ...2 The DP23 DP28 camera 2 1 Scope of supply Camera USB camera cable Instructionmanual 2 The DP23 DP28 camera 7...

Page 8: ...iguration refer to page 14 Youcanuse the following Olympus software applications Software application Minimum version cellSens Life science image analysis software 3 1 1 OLYMPUS Stream Materials solut...

Page 9: ...ront ofthe camera After starting the software the LED indicates the following statuses LED Status The LED flashes The camera is being initialized The LED flashes continuously There is a camera error C...

Page 10: ...8 92mm diagonal Maximum resolution 3088x2076pixels 6 41 million pixels Camera port of the microscope C Mount Input output On the camera USB 3 1 type C with lock screws On the computer or DP2 AOU USB...

Page 11: ...P2 AOU USB 3 1 type A Resolution Frame rate Exposure time 4104 x2174 Full resolution 32fps 27 s 15s 2168x2168 Square 33fps 2052x1086 High speed 64 fps 2052x1086 High sensitivity 32fps 3840x2160 4K 33f...

Page 12: ...meet the operating and storage conditions Operating environment Ambient temperature 5 C 40 C Relative humidity 5 85 without condensation Altitude Up to 2000m Storage conditions Ambient temperature 20...

Page 13: ...TV1XC U TV1X U CMAD3 O O U TV0 63XC O U TV0 5XC 3 O U TV0 35XC 2 MVX TV1XC O O MVX TV0 63XC O GX TV0 7XC O GX TV0 5XC O GX TV0 5XC DP O 0 5XC integrated in SZ61TR O O Compatible Limited compatible Th...

Page 14: ...dia drive Optical drive double layer capable Computer input device Recommendation 3 button mouse with wheel Keyboard Operating system Microsoft Windows 10 64 Bit 3 3 Restrictions on use DP23 DP28 with...

Page 15: ...engthis long see examples below the peripheryofthe field ofview maybe obscured depending onthe observationtube and objective used together Examples whenthe intermediate tubelengthis long n 2 or more i...

Page 16: ...is almost completelyclosed This flare becomes less noticeable ifyou openthe aperture diaphragm AS No support ofsimultaneous image acquisitionusing severalcameras Youcanconnect severalDP23 DP28 camera...

Page 17: ...t camera adapter to the camera port of the microscope Checking the camera s orientation Ifthe camera is not attached inthe correct orientation the camera image does not matchthe image visible throught...

Page 18: ...ompliance with the EMC basic standards be ensured 1 Connect the USB type Cplug a to the camera s USB type C socket b and secure it withthe two screws c 2 Connect the USB camera cable s USB type A plug...

Page 19: ...are Read the cellSens OLYMPUS Stream installationmanualbefore installing the software Whenyoupurchase DP2 AOU the required software is pre installed TWAIN Driver DP2 TWAIN DP2 TWAIN is available onlya...

Page 20: ...5 Acquiring images Youcanfind detailed instructions inthe instructionmanualor inthe Help ofthe software youare using Example ofthe acquisitionprocess for brightfield images DP23 DP28 20...

Page 21: ...r oilsmudges onthe protective glass carefullycleanit witha cleanlens clothmoistened withpure alcohol Cleaning the housing Parts other thanthe glass components should be cleaned witha clean cloth Do no...

Page 22: ...ontinuously see page 17 Problem Live image is not displayed Possible cause Remedy The illumination of the microscope is not turned on Switch on the microscope illumination The light path selector of t...

Page 23: ...mages Close the loaded images Then acquire the next snapshot Problem The image is too bright Possible cause Remedy The exposure compensation is set too high to the side Set the exposure compensation t...

Page 24: ...ters The manual exposure time is set too low Increase the manual exposure time Problem The colors ofthe image are inaccurate Possible cause Remedy The reference area for white balance was not selected...

Page 25: ...cal aperture and focus the microscope on the sample The field diaphragm is too wide open Narrow the field aperture appropriately and focus the microscope on the sample Lens components of the microscop...

Page 26: ...calOlympus support ifyouhave anyquestions about the product The addresses canbe found onthe following websites Life Science Solutions https www olympus lifescience com en contact us IndustrialSolution...

Page 27: ...directive onWaste of Electricaland ElectronicEquipment this symbolindicates that the product must not be disposed ofas unsorted municipal waste but should be collected separately Refer to your local a...

Page 28: ...tructions it maycause harmfulinterference to radio communications However there is no guarantee that interference willnot occur ina particular installation Ifthis equipment does cause harmfulinterfere...

Page 29: ...ericas Corp Address 48 Woerd Ave Waltham MA 02453 U S A Phone Number 781 419 3900 FCC Supplier s Declaration of Conformity The supplier hereby declares that the product Product name Optical Microscope...

Page 30: ...umber RegistrationNo DP23 CU R R OIS 68000000 BasicModelNumber RegistrationNo DP28 CU R R OIS 69000000 Manufacturer CountryofOrigin Olympus Soft Imaging Solutions GmbH Germany China RoHS conformity Ch...

Page 31: ...14 Japan OLYMPUS EUROPA SE CO KG Wendenstrasse 20 20097 Hamburg Germany OLYMPUS CORPORATION OF THE AMERICAS 3500Corporate Parkway P O Box610 Center Valley PA 18034 0610 U S A OLYMPUS CORPORATION OF AS...