OLYMPIC VETERINARY 50901 Owner'S Manual Download Page 4

4

Introduction

The Olympic Dental Table is a fully adjustable dental table designed to provide better patient presentation,  
save time and improve operator comfort. 

The Dental Table is adjustable in four ways to meet the needs of the operator: Height adjustable from 29" to 41". 
Table Top can be tilted down to a maximum of 10 degrees for drainage. Each Table Top panel can be lifted up  
to 45 degrees for dorsal positioning. Instrument tray adjustable from left to right of table. 

The Olympic Dental Table also has a complete, self-contained drainage system, which collects any fluids from  
the Table top as well as fluids passing through the Dental Screen in a removable Drain Pan located under the 
Head Support. 

Safety

Please read and follow the instructions in this manual, including all safety instructions and precautions,  
carefully and completely. 

The user should be aware that the Dental Table is a powerful machine with moving parts capable of causing injury 
if proper precautions are not taken. The lift is raised and lowered by means of an electrical actuator, and care 
must routinely be taken to assure that hands, feet and other body parts are not in the path of the lift mechanism.

Caution: Do not use the Dental Table for patients weighing more than 250 pounds.

Unpacking and Setup

Warning: The Olympic Dental Table is heavy  
and requires at least 2 people to unpack and  
move in order to avoid injury to staff or damage  
to the product.

Caution: Do not lift the table by grasping the  
table top as this can result in permanent damage  
to the unit. 

Note: If you suspect concealed shipping damage, 
please save all packaging and contact Olympic 
Veterinary immediately at 1-800-789-6867.

1. 

Move the pallet to a level location as close 
 as possible to the intended installation site.

2. 

Remove the shrink wrap and the cardboard lid,  
then completely peel off the cardboard shroud.

3. 

Cut the 2 tie-down straps securing the cardboard 
carton to the table top and set the carton aside  
until the table has been rolled to its final destination.

4. 

The table is bolted to the floor of the pallet with 
4 L-shaped brackets 

A

 secured by 12 hex head 

screws. Remove all 12 screws using the included  
Hex Head Wrench.

5. 

Remove the 2x4 retaining board 

B

 located in front  

of the dental table from the floor of the pallet by 
sliding it out of the slotted enclosure.

E

D

A

B

C

Figure 2

Summary of Contents for 50901

Page 1: ... Olympic Dental Table Model 50901 50903 Serial 9311 SE 36th Street Unit 220 Mercer Island WA 98040 Phone 800 789 6867 Fax 206 905 0839 Web www OlympicVeterinary com Email Info OlympicVeterinary com OLYMPIC VETERINARY ...

Page 2: ...e it is recommended you write this serial number on the front of this manual Table of Contents Component Identification 3 Introduction 4 Safety 4 Unpacking and Setup 4 Assembly Installing the Head Support and Dental Tray 5 Installing the Instrument Tray 5 Quick Start Instructions 5 Operation Loading Unloading Patients 6 Height Adjustment 6 V Table Dorsal Positioning Adjustment 6 Tie down Cleats 6 ...

Page 3: ...nting Platform for Compressor D Power Strip E Power Cord F Instrument Tray Arm with Mounting Plate G Instrument Tray H Tray Arm Double Socket I Tilt Lever J V Positioner Lock Levers K Tie down Cleats L Drain Trough M Table Top Panels N Front Head Support Thumbscrews O Rear Head Support Thumbscrews P Removable Drain Pan Q Dental Screen R Drain Pan Retention Knob S Head Support T Lift Column Figure ...

Page 4: ... routinely be taken to assure that hands feet and other body parts are not in the path of the lift mechanism Caution Do not use the Dental Table for patients weighing more than 250 pounds Unpacking and Setup Warning The Olympic Dental Table is heavy and requires at least 2 people to unpack and move in order to avoid injury to staff or damage to the product Caution Do not lift the table by grasping...

Page 5: ...d in Velcro and should now be pressed against the Velcro on the mounting plate to create a solid connection Note The Velcro affixed B Tray is designed to remain permanently attached to the Dental Table and to serve as a base on which removable B Trays can be nested and removed for cleaning Plastic Velcro material must be pressed firmly to fully engage Note If you ordered model 50903 you have recei...

Page 6: ...with additional table adjustments When a procedure is completed the table should be returned to a horizontal position with its 2 table V panels flattened before removing the patient Height Adjustment The height of the Olympic Dental Table is infinitely adjustable from 29 to 41 and may be adjusted at any time during a procedure to provide maximum comfort to the operator or to provide better visuali...

Page 7: ... one of these ports The other 4 ports are available as needed Moving the Dental Table If at any time you wish to move the Dental Table disconnect the Power Cord E and unlock all four caster brakes To unlock a caster step on the brake release lever When the caster is locked a red window will be visible on the caster CAUTION The Olympic Dental Table is heavy and requires at least two people to move ...

Page 8: ...Specifications Olympic Dental Table Model 50901 50903 Capacity 250 pounds with centered load V Positioner Range zero to 45 degrees each side Table size 21 W x 50 L Horizontal Tilt zero to 10 degrees Headrest size 21 W x 12 L Casters 4 in line locking Overall maximum dimensions 21 W x 62 L x 29 H Power 120V 60Hz Height Range 29 to 41 Weight 275 pounds Model 50901 Olympic Dental TableTM 1 Swivel Arm...

Page 9: ...E THIS IS NOT THE STREET ADDRESS TO BE USED FOR RMA RETURNS Detailed shipping instructions will be provided by customer service when a RMA is issued 509 IM E0611G 3 year Unconditional Warranty All Parts and Labor Should your Olympic Dental Table as the result of normal use require any repair within 3 years after purchase all replacement parts and labor will be furnished free of charge ...