SENSORS IN DETAIL
Setting Up the Motion Detector
Various settings can be defined using the
jumpers on the PCB of the motion detector.
Ideally, you should define any settings before
assembling the motion detector at the instal-
lation location.
1
Open the battery compartment by press-
ing the locking latch on the top of the mo-
tion detector down using an appropriate,
pointed object.
2
Set the jumpers regarding to the pre-
ferred settings.
Important! Risk of property damage through
electrostatic discharge. Use insulated tools
when adjusting the jumpers on the motion
detector’s PCB. Do not make contact with the
jumpers or PCB with bare hands. Ensure not
to loose the jumpers.
1
3
2
5
4
1 Sensitivity
(
H
= high, L = low)
2 Battery low signal
(
ON
/ OFF)
3 Time setting (5s = 5 seconds pause between
motion detection, 5 min. = 5 minutes pause)
4
Sabotage Protection
5
LED on/off (
ON
= LED on, OFF = LED off)
Settings which appear in bold print are the
standard settings.