Olympia P-3210 Installation And Maintenance Instructions Download Page 2

Thank you for purchasing this quality product. Olympia products are rigorously tested to provide long service 

under normal conditions. Prior to installation, familiarize yourself with this parts diagram. Make sure that you have 

all of the illustrated parts for your Olympia product before installation.

ITEM #

DESCRIPTION

A

OP-190013C

OP-190009C

Metal Handle-Cold

Acrylic Handle-Cold

B

OP-140004V

OP-140005V

Metal Handle-Diverter

Acrylic Handle-Diverter

C

OP-190013H

OP-190009H

Metal Handle-Hot

Acrylic Handle-Hot

D

OP-440012

Flange

E

OP-440013

Plastic Escutcheon Nipple

F

OP-340002

Stem Unit-Diverter

G

OP-340001

Stem Unit-Cold,Hot

H

OP-440015

Union

I

OP-440016

Nut

J

OP-640001

Shower Flange

K

OP-640002

Shower Arm

L

OP-640031

1.75 GPM Shower Head

M

OP-640014

Tub Spout

N

OP-440017

Guard Cover

O

OP-640015

1/2” IPS Diverter Tub Spout (For 

P-1210 & P-1220)

INSTALLATION INSTRUCTIONS

Tools you will need:

Plumbers Putty

• 

Teflon Tape

• 

Screwdriver

• 

Flexible Supply Lines

• 

Pipe Wrench

• 

Adjustable Wrench

• 

Basin Wrench

• 

Soft Cloth

• 

Tub And Shower INSTALLATION:

Carefully shut off both hot and cold water supplies. Cover the drain with a soft cloth to prevent the 

1. 

loss of any parts. If this installation is for a replacement, carefully remove the existing valve and 

clean the entire mounting surface.

2a.  For ½” threaded pipe connection: connect water supplies to left (hot) and right (cold) valve body 

inlets with Teflon Tape.

2b.  For ½” sweat copper tubing connections: remove rubber and plastic parts to prevent damage. Sol-

der water supplies to left (hot) and right (cold) valve body inlets.

Insert shower flange (J) onto the shower arm (K). Install shower arm (K). Then Install Showerhead 

3. 

(L). Apply Teflon Tape at threaded Connections.

Install tub spout (M). Place handles (A,B,C) on valve stems (F,G) and turn on hot and cold water to 

4. 

full open for one minute to flush thoroughly. Check for leaks.
Shut off water. Remove handles (A,B,C). Install trim flanges (D). Re-install handles (A,B,C).

5. 

Olympia Faucets, Inc. © 2011

For more care information or trouble shooting inquiries 

about your Olympia product, please call: 

OLYMPIA FAUCETS, INC. 

(888) 772-7701 

Central Standard Time: 8:00am ~ 7:00pm

www.olympiafaucets.com

ITEM #

DESCRIPTION

1

OP-490037

Screw

2

OP-440014

Seat

Reviews: