background image

Thank you for purchasing this quality product. Olympia products are rigorously tested to provide long service 

under normal conditions. Prior to installation, familiarize yourself with this parts diagram. Make sure that you have 

all of the illustrated parts for your Olympia product before installation.

ITEM #

DESCRIPTION

A1

OP-190010C,H

Lever Handle Cold, Hot (For 

L-733X)

A2

OP-190015C,H

Lever Handle Cold, Hot (For 

L-737X)

B

OP-490006

Bonnet Nut

C

OP-390004

Cartridge–Brass Post

D

OP-490007

Escutcheon & Gasket

E

OP-590002

Valve Mounting Kit

F

OP-490041

Springs & Seats

G

OP-590001

Supply Nut

H

OP-230001

‘C’ Style Spout

I

OP-430001

Spout Mounting Kit

J

OP-490009

“Y” Connector & Washer

K

OP-490008

Flex Connector Hose

L

OP-630004

OP-630002

50/50 Pop-Up Drain

Brass Pop-Up Drain

M

OP-490011

3/32” Aleen Wrench

1

OP-490029

Allen Screw

2

OP-490010

1.5 GPM Aerator

INSTALLATION INSTRUCTIONS

Tools you will need:

Plumbers Putty

• 

Teflon Tape

• 

Screwdriver

• 

Flexible Supply Lines

• 

Pipe Wrench

• 

Adjustable Wrench

• 

Basin Wrench

• 

Soft Cloth

• 

FAUCET INSTALLATION:

Carefully shut off both hot and cold water supplies from under the sink. Plug the sink drain with a soft 

1. 

cloth to prevent intrusion of debris or the loss of any faucet parts. If this installation is for a replace-

ment, carefully remove the existing faucet and clean the entire surface of the sink mounting holes.
Lead spout (H) though the center hole. Slide mounting bracket (I) along the shank of the spout from 

2. 

underneath of the sink and use a 27/32” socket to tighten mounting nut (I). Place rubber washer (J) 

in ‘Y’ connector (J) and tighten to thread end of spout (H). CAUTION: Do not overtighten.
Carefully install supply valves in both remaining sink holes. Make sure both outlet hoses on the 

3. 

supply valves face to ‘Y’ connector (J). Assemble and adjust friction washer and locknut (E) so that 

the top of the supply valve is approximately 1-3/4” (45mm) above the mounting surface. Assemble 

gaskets and escutcheon (D). Use adjustable wrench to tighten.
Attach hot and cold (indicators ”C” or “H” inside the handle hub) handles (A1 or A2) onto cartridge 

4. 

(C). Use 3/32” hex wrench to tighten set screws (1). CAUTION: Do not overtighten.
Tighten both compression nuts on hoses of supply valve to ‘Y’ Connector (J). Connect both hot inlet 

5. 

tube (LEFT INLET) and cold inlet tube (RIGHT INLET) to supply lines. NOTE: If additional adapters 

or supply lines are required, they may be purchased from the same location where this faucet was 

purchased. Use with teflon tape when attaching faucet to supply lines.

Use sealant to caulk around spout (H).

6. 

POP-UP DRAIN ASSEMBLY INSTALLATION:

Thread mounting nut and bottom gasket of the pop-up drain assembly (K) onto the drain body. Wrap 

1. 

bottom threaded end of the flange with teflon tape and place adequate amount of plumbers putty 

around the underside of flange.
Gently slip the drain body up through the drain opening. Screw flange onto drain body, holding the 

2. 

drain body in position with the pivot rod opening facing the back of the sink. Tighten the mounting nut 

securely with a wrench.
Place pivot rod in pivot rod opening. Slide pivot nut over pivot rod and thread it onto the drain body.  

3. 

Hand tightens until it is snug. CAUTION: Be careful not to overtighten.
With the lift rod in position on the faucet lift rod hole, lift the rod through the lift rod strap and secure 

4. 

with the set screw.
Guide the pivot rod through one of the holes on the lift rod strap and secure it with the spring clip, 

5. 

then adjust the height of the lift rod by resetting the set screw.

FINAL PRODUCT INSTALLATION:

Turn on the hot and cold water supplies. Check all around for any minor joint leaks. NOTE: Inspect 

1. 

for any leaks around the connections to the supply lines.

Remove aerator (2) from end of spout (H). Turn on both sides of handles to flush both water lines 

2. 

allowing water to run through for one minute. Replace aerator (2).

CAUTION: MAKE SURE TO TIGHTEN THE AERATOR SECURELY AFTER FLUSHING THE WATER 

LINES TO PREVENT FROM FUTURE WATER SEEPAGE.

Olympia Faucets, Inc. © 2013

For more care information or trouble shooting inquiries 

about your Olympia product, please call: 

OLYMPIA FAUCETS, INC. 

(888) 772-7701 

Central Standard Time: 8:00am ~ 7:00pm

www.olympiafaucets.com

Reviews: