10
G
Self-Diagnosis
Display
Cause
Solution
E0
The sensor is soiled or damaged.
Remove the coins and clean the sensor.
EC
The sensor for the coin tray is soiled
or damaged.
Clean the sensor.
E1
-
E8
The respective counting sensor is soiled
or damaged.
Clean the respective sensor.
If there is no improvement after cleaning, refer to Chapter
GUARANTEE
and call the service number.
Technical specifications
Model
CC 202
Infeed funnel
300 - 500 coins
Counting speed
Approx. 215 coins/minute
Power supply
230 V/ 50 Hz
Power consumption
45 W
Permissible ambient temperature
0 to 40 °C; 30 to 80% relative humidity
Dimensions
321 x 321 x 270 mm
Weight
4.5 kg
Switch the machine off prior to cleaning.
Clean off dust with a soft, clean brush or a soft, lint-free
cloth.
Clean the sensors after each use.
Disposal
The adjacent symbol indicates that
old electric
al and electronic apparatus and batteries
must be disposed of separate from normal
household waste, in compliance with legal require
ments.
Packaging materials
must be disposed of according to
local regulations.