background image

Page 

3

 from

 4

Page 2 from

 4

ELECTRICAL CONNECTIONS

1

1

2

2

3

3

4

4

5

Dismantle the luminaire by pushing the lock/unlock hooks 
on each side and pull it down. 
Pass thru the cables from the entry hole and connect them 
as shown in the picture. 

N

 for neutral 

L

 for live wire and 

PE

 for ground (optional).   

Connect the battery’s connector to the respective 
connector on P.C.B.
Place upwards the luminaire until the plastic hooks are 
securely locked.
Power on the device

.

 

FLAG MOUNTING INSTALLATION (optional)

Install the flag mounting base on the wall (page 3) and 
perform the respective steps of the electrical connections. 

SURFACE MOUNTING ON A WALL (single sided)

Dismantle the luminaire, install the plastic bracket on the 
wall (page 3) and perform the respective steps of the 
electrical connections.

CEILING INSTALLATION

Dismantle the luminaire, install the plastic bracket on the 
ceiling (page 3) and perform the respective steps of the 
electrical connections.

HANGING INSTALLATION (optional)

Install the mounting base (tube) on the ceiling (page 4) 
and perform the respective steps of the electrical 
connections.

NOTE!! After finishing the installation you must power 
the luminaire for at least 24 hours for battery charging 
to perform the named autonomy. 

INSTALLATION INSTRUCTIONS

SURFACE MOUNTING ON A WALL

 (

single side luminaire

)

FLAG MOUNTED ON A WALL

MOUNTING METHODS

CEILING MOUNTED

If necessary place the included 
spacers to mount the base.

If necessary place the included 
spacers to mount the base.

Test
button

Charge Lamp fault

Battery
fault

Indications

device enters regular

 

operation mode.

Changing the operating mode

Press  and  hold  the  TEST  button  for  more 
than 5 seconds

.

 

T

he l

uminaire

 will erase first 

the  errors  (3  LED  indicators  will  light  in 
succession)  and

 

after

 

2  seconds  the  LED 

Lamp  Fault  will  remain  lit  steadily. 

When  the

 

TEST  button

  is  released

,  the  l

uminaire

  will 

change between 

maintained or no-maintained

 

mode.

  The  change  is  recorded  permanently 

in it’s memory.

Indication  LED  status  (with  connected 
mains power supply).

Charge 

On:

 

Good charge condition.

Οff:

 

No battery 

(

No charging current 

or disconnected battery

).

Lamp fault 

Οn

 

(with LED strip off)

:

 

faulty LED strip (must 

be replaced).

Οn

  (with  LED  strip  on)

:

 

Problem  in  the  back 

up circuit of the LED strip (must be checked by 
an authorized personel).

Off:

 

 Good LED strip.

Battery Fault

 

Ο

ff

:

 

Battery OK. 

Blink

  (

With  Charge  LED  ON):

  Autonomy  or 

low  battery  problem 

(the  battery  must  be 

replaced).

Blink

 

(

With  Charge  LED  Off): 

No  charging 

current or disconnected battery

.

ΑΤΤΕΝΤΙΟΝ

!!!

1.  Operations  for  installation,  maintainance  or 
testing  must  be  done  by  authorized  personel 
only

.

2. 

The device must be connected to the mains 

power supply through a fuse  that is dependent 
on the total amount of the line’s  power load

.

In  case  of  battery  or  lamp  replacement, 

these  must  be  replaced  by  parts  with  same 
type,  by  the  manufacturer  or  by  a  competent 
person.

                

t i

 

in  battery  recycling 

points. Do not incinerate.

3. 

4.  In  case  of  inactive  use  for  a  period  greater 
than  2  months,  disconnect  the  battery  by 
pulling out the battery’s connector.

 

5

I

s not allowed to discard batteries in to 

common  trash  bins,  they  must  be 
discarded  only 

922502500_09_001

922502500_09_001

L
N
PE

Reviews: