olympia electronics OLY-1004/LT/WP Installation Instructions Download Page 2

1

2

3

4

5

A

B

A

1
1
1
1

Luminaire
Set of Pictograms
Mounting accessories
Manual

1

2

Pictogram Installation

3

Mounting Methods

2

2

1

1

A  duration  test  can  be  conducted  by  pushing  the 
button  steadily  for  5  to  10  seconds.  In  order  to  be 
performed,  the  mains  power  supply  should  be 
connected  and  the  battery  should  be  fully  charged. 
The luminaire enters emergency mode, the CHARGE 
LED is turned OFF and the BATTERY FAULT LED starts 
blinking. Its duration is the stated autonomy duration 

Manual Autonomy Test

Remove  the  diffusor  and  then  by  pressing  the  test 
button briefly an operation test is initiated. The light 
source  and  the  emergency  circuit  of  the  device  are 
tested. The manual test can be conducted only if the 
mains  power supply  and  the  battery  are  connected. 
During this test period the LAMP TEST LED will  blink. 
The  battery  must  have  adequate  charge.  This  test 
lasts for 3 seconds.

Manual Operational Test

Two  additional  labels  are  included  in  the  package. 
one  for  3  hours  duration  (180)  and  one  for  8  hour 
duration (480). Depending on the selected duration, 
the  installer  must  cover  the  default  1  hour  (60) 
printing  with  one  label  that  has  the  required 
duration. Please take notice of the orientation of the 
label.

Technical Label Installation

The user can select one of the 3 available minimum 
autonomy durations 1 hour, 3 hours and 8 hours. The 
selection  must  be  done  while  the  luminaire  is 
disconnected  from  AC  and  battery  supplies.  The 
selection is achieved through Switches 2 & 3 of DS1 
as shown below.

Autonomy Duration Selection

These  devices  are  used  indoors  and  outdoors                       

o

(t  -25-40 C)  in  places  where  emergency  light  is 
needed, its suitable for freezers. Each device must be 
permanently  connected  to  mains  power  supply.  In 
normal  operation  the  battery  is  charging.  The  light 
source  can  be  either  on  or  off,  depending  on  user’s 
choice. In case  of a mains power supply failure, the 
device enters emergency mode and the illumination 
LED  turns  on.  When  the    mains    power    supply  is 
restored the device turns to normal operation.

6. 

I

s  not  allowed  to  discard  batteries  into 

t  i

common  trash  bins,  they  must  be  discarded 
only 

in  battery  recycling  points.  Do  not 

incinerate.

5.  In case of inactive use for a period greater than 2 

months, disconnect the battery by pulling out the 
battery’s connector. 

4.  In  case  of  battery  replacement,  it  must  be 

replaced by the same type, by the manufacturer 
or a competent person.

                

3.  The  device  must  be  connected  to  the  mains 

power  supply  through  a  circuit  breaker    that  is 
depends on the total line’s  power load.

2.   Always use in any case round mains cable, with a 

diameter  of  5-10mm  (H05RN-F  type  2x1mm²  or 
any  other  type,  at  least  equal  to  it’s  mechanical 
and electrical properties). ATTENTION!! The cable 
must  not  be  deformed  in  any  way  (This 
requirement is important to ensure the ΙΡ rating).

1.  Operations  for  installation,  maintainance  or 

testing  must  be  done  by  authorized  personnel 
only.

ΑΤΤΕΝΤΙΟΝ!!!

When  the  luminaire  is  used  without  the  pictograms 
or  the  SP-1100  and  you  require  more  light  output 
then remove the lens that covers the LEDs.

Lens Removal

The  Automatic  Autonomy  Test  is  conducted  every  6 
months and measures the device’s back up operation 
and  emergency  duration.  This  test  includes  all 
functions of the Manual Autonomy Test.

Automatic Autonomy Test

     

This test includes all the operations that are provided 
in  Manual  Operational  Test  and  is  conducted 
automatically every 15 days and lasts 3 seconds.

Automatic Operational Test

of the luminaire. If at the end of the test the autonomy 
is lower than the nominal, the BATTERY FAULT LED will 
lit and battery needs to be replaced. If the result of the 
test is good then the luminaire enters charging mode 
and the CHARGE LED starts blinking until the battery is 
fully charged. 

Oly luminaires can be surface mounted on walls or ceilings. For these mounted installations,  special 
accessories are included.

Wall

bottom

view

Wall installation

Ceiling installation

Ceiling

*  ATTENTION!!!  The  below  mounting  methods  can  be  done  after  request  of  the  necessary 

mounting accessories!!

Extra Mounting Methods *

Suspended ceiling installation 

with mounting accessory

A-3018

Suspended installation with A-3018 accessory

The  luminary  can  be  installed  in  a  suspended 
ceiling.

A marking panel (

SP-1100

) can be installed on the luminary pointing the desired direction.

Suspended ceiling installation 

with mounting accessories  

and marking panel

Ceiling installation 

with marking panel

General

5

6

7

7

8

8

9

NOTE!! 
After  finishing  the  installation  you  must  power  the  luminaire  for  at  least  24  hours  in  order  to 
completely charge the battery. The rated autonomy duration can be achieved after that time.

Package Contents

2

923100410_09_003

923100410_09_003

923100410_09_003

Drill  one  of  the  5  available  holes  with  a  16-18mm  drill  bit.  Install  the  included  rubber  gasket  and  pass 
through the power cables. Install the included tie (if needed) to fasten and securely the power cables. 

3

4

1h

(default position)

3h

8h

Battery Connection

Attention!!

  The  6  plastic 

latches  (A)  must  be  secured 
(click sound). This requirement 
is  important  to  ensure  the 
IP65  rating.  Power  on  the 
luminary.

ON

1 2 3 4

ON

1 2 3 4

ON

1 2 3 4

6) Autonomy Duration Selection

(Read on General Informations, Page 1)

7 a) Permanent Maintained Operation

7 b) Non-Maintained Operation

7 c) Controlled Maintained Operation of the lamp

ON

1 2 3 4

11

10

Ν

 for neutral, 

L

 for live wire

WARNING!!

 Isolate the mains power supply before making the connections.

Ν

 for neutral, 

L

 for live wire

 WARNING!!

 Isolate the mains power supply before making the connections.

Description

Indications LED Status

BATT.

FAULT

(yellow)

LAMP
FAULT

(red)

CHARGE

(green)

Fully charged

Charging

Battery fault or
emergency mode

Operational test

Operational failed

Autonomy test

Duration fault

Note:

Permanently

ON

Blink

Indifferent

Off

N
L

Link

N
L

1

Installation Instructions

or

Switch number 4 of DS1 
must be in ON position. 

ON

1 2 3 4

Switch number 4 of DS1 
must be in OFF position. 

and

ON

1 2 3 4

Switch number 4 of DS1 
must be in OFF position. 

and

N
L

External

switch

1

2

1. Install the pictogram you need in the diffuser, be careful to 
secure it on the 3 plastic holders. 
2. Refit the diffusor with the pictogram to the luminary.

Reviews: