and emergency duration. This test is
conducted automatically every 6 months. In
order to be performed, the mains power
supply and the battery should be connected
and fully charged. If the battery is not fully
charged, the test is postponed until the battery
is completely charged. If during this test, the
autonomy is less than nominal then the battery
fault led turned on continuously and the
battery must be replaced.
Back Up Operation
The autonomous duration of battery during
emergency mode is at least the one that is
stated
in
the
list
of
the
technical
characteristics. During emergency mode, a
light source test is also performed.
Resetting Errors
Push the TEST/RESET button for 5 seconds,
to delete all the indicated LED errors (page 3).
Then the luminaire enters regular operation
mode.
Indication LED status (with connected
mains power supply).
Charge
On:
Good charge condition.
Οff:
No battery (No charging current
or disconnected battery).
Lamp Fault
with L1 connected to L
Οn (with LED strip off):
Faulty LED strip
(must be replaced).
Οn (with LED strip on):
Problem in the back
up circuit of the LED strip (must be checked by
an authorized personnel).
Off:
Good LED strip.
Battery Fault
Οff:
Battery OK.
Blink (With Charge LED ON):
Autonomy or
low battery problem
(the battery must be
replaced).
Blink (With Charge LED Off):
No charging
current or disconnected battery.
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance or
testing must be done by authorized personel
only, after a mains interruption.
2. The device must be connected to the mains
power supply through a fuse dependent on the
total amount of the line’s power load.
In case of battery or lamp replacement,
these must be replaced by parts of the same
type, by the manufacturer or by a competent
person.
3.
4. In case of inactive use for a period greater
than 2 months, disconnect the battery by
pulling out the battery’s connector.
5.
I s not allowed to discard batteries in to
common trash bins, they must be
discarded only
t i
in battery recycling
points. Do not incinerate.
NOTE:
LED= Light Emitting Diode
LABELING EXPLANATION:
X:
Self contained
1:
Maintained (*)
A:
Including test device
G:
Internally illuminated
*480:
8 hours duration
(*) Maintained operation: The luminaire lights
its illumination source, when it is powered by
the mains power supply or not.
Non Maintained operation: The luminaire lights
its illumination source, only in power supply’s
failure.
Note!! The installer should fill in, on the
specification label, the letter
G
if the luminaire
is used as a safety sign.
NOTE!! After finishing the installation you
must power the luminaire at least for 24
hours for battery charging to perform the
nominal autonomy.
Battery replacement
It can be done only by a competent person
and after the mains interruption.
1. Unfasten the 4 retaining screws (not all the
way) (step 10 of the installation instructions)
and remove the diffusor.
2. Unfasten the 2 retaining screws (step 9 of
the installation instructions) and remove the
reflector.
3. Remove the old battery and place a new
one of the same type and characteristics.
4. Replace the removed parts (previous steps
1,2).
The light source contained in this luminaire
s h a l l o n l y b e r e p l a c e d b y t h e
manufacturer, or his agent, or a similar
qualified person.
NOTE! The light source is non-user
replaceable.
923940000_09_009
Page 2 from 4
4
X 1
8 0
A G