background image

Page 2 from

 

3

the  battery  should  be  connected  (the 
battery  should  be  charged)

If  the  battery 

is  not  charged

the  test  is  postponed

 

until 

the battery is completely charged. If during 
the  Automatic  Autonomous  Test  the 
luminaire’s  duration  is  lower  than  the 
n o m i n a l ,   t h e n   t h e   b a t t e r y   m u s t   b e  
replaced. 

Back Up Operation

The autonomous duration of battery during 
emergency mode is at least the one that is 
stated  in  the  technical  characteristics. 
During  emergency  mode,  a  LED  strip  test 
is also performed.

Resetting Errors

Push  the  TEST/RESET  button  for  5 
seconds,  to  extinguish  all  the  indicated 
LED  errors  (page  3).  Then  the  luminaire 
enters regular

 

operation mode.

Indication LED status 
(with connected mains power supply).

Charge 

On:

 

Good charge current.

Οff:

 

No  battery 

(

No  charging  current  or 

disconnected battery

).

Lamp Fault

Οn:

 

Faulty LED strip.

Off:

 

Good LED strip.

Battery Fault 

Ο

ff

:

 

Battery OK. 

Blink

  (

With 

Charge  LED

  ON):  Autonomy 

or low battery problem

(the battery must be replaced).

Blink

 

(

With 

Charge LED

 Off):

 

No  charging  current  or  disconnected 
battery

.

ΑΤΤΕΝΤΙΟΝ

!!!

1. Operations for installation, maintainance 
or  testing  must  be  done  by  authorized 
personel only

.

2. 

The  device  must  be  connected  to  the 

mains  power  supply  through  a  fuse 
dependent by the total amount of the line’s  
power load

.

3. 

In case of battery or lamp replacement, 

these  must  be  replaced  by  parts  of  the 
same  type,  by  the  manufacturer  or  by  a 
competent person.

4.  In  case  of  inactive  use  for  a  period 
greater  than  2  months,  disconnect  the 
battery  by  pulling  out  the  battery’s 
connector.

 

5. 

I s not allowed to discard batteries in 

t i

to common trash bins, they must be 
discarded  only 

 

in  battery  recycling 

points. Do not incinerate.

NOTE: 

LED= Light Emitting Diode

LABELING EXPLANATION:
X: 

Self contained 

  

1: 

Maintained (*)

A: 

Including test device

   

480: 

8 hour duration

(*) 

Maintained operation: The luminaire 

lights its illumination source, when it is 
powered by the mains power supply or not

Non Maintained operation: The luminaire 
lights its illumination source,

 

only in  power 

supply’s failure. 

NOTE!! After finishing the installation 
you must power the luminaire at least 
for 24 hours for battery charging to 
perform the nominal autonomy. 

Battery replacement

 

1. Unfasten the 4 retaining screws 

(

step 10 

of the installation instructions

)

 and remove 

the diffusor.
2. Unfasten the 2 retaining screws step 9 of 
the installation instructions and remove the 
reflector.
3. Remove the old battery and place a new 
on of the same type and characteristics.
4. Replace the removed parts (previous 
steps 1,2).  

923940002_09_003