background image

Page 2 from 4

 

and  the  capacitors  should  be  connected  and 
fully  charged.  If  the  capacitor  is  not  fully 
charged,  the  test  is  postponed  until  the 
capacitor is  completely charged. 

Back Up Operation

The  capacitor’s  autonomous  duration    during 
emergency  mode  is  at  least  the  one  that  is 
stated 

in 

the 

list 

of 

the 

technical 

characteristics.  During  emergency  mode,  a 
LED strip test is also performed.

Resetting Errors

Push  the  TEST/RESET  button  (page  3)  for 
>10  seconds,  to  delete  all  the  indicated  LED 
errors  .  Then    the  illumination  sign  enters 
regular operation mode.

Test switch

Pressing  the  test  switch  less  than  5  seconds 
will initiate a light source test (last for 3 secs). 
Pressing  the  test  switch  between  5  to  10 
seconds  will  initiate  a  manual  capacitor 
duration test. This test will not be  started if the 
capacitor  is  not  fully  charged  (i.e.  If  the  green 
LED is flashing). If the test switch is pressed 

for more than 10 seconds, the illumination sign 
will be reset (delete all errors).

ΑΤΤΕΝΤΙΟΝ!!!

1.  Operations  for  installation,  maintainance  or 
testing  must  be  done  by  authorized  personel 
only.
2.  The  luminaire  must  be  connected  to  the 
mains  power  supply  thru  a  fuse  dependent  by 
the total amount of the line’s  power load.
3.In  case  of  capacitors  or  lamp  replacement, 
these  must  be  replaced  by  parts  of  the  same 
type,  by  the  manufacturer  or  by  a  competent 
person.

t i

  in  battery  recycling 

points. Do not incinerate.

4. In case of inactive use for a period greater 
than  2  months,  disconnect  the  battery  by 
pulling  out  the  battery’s  connector  when  is 
fully charged. 

5. 

I

s not allowed to discard batteries in to 

common  trash  bins,  they  must  be 
discarded  only 

923900000_09_007

Status of LEDs

Led status explanation

GREEN

YELLOW

RED

Normal

Charging

C

 duration test (auto or manual)

apacitor’s

Capacitor’s fault

Capacitor’s fault and light source fault

Charger and 

 fault (or mains off and battery fault)

capacitor’s

Charger and light source fault (or mains off and 

 fault)

light source

Charger, 

 and light source fault (or mains off, capacitor and 

 fault)

capacitor

light source

Light source test

Light source fault

Continuous ON

Continuous OFF

Flashing at 1,2 Hz

Charger’s fault, capacitor not connected or mains off

LEDs

Description