olympia electronics GR-579/L/90/WP Quick Start Manual Download Page 2

Page

 2

 from

 

4

Back Up Operation

The  autonomous  duration  of  battery  during 
emergency  mode  is  at  least  the  one  that  is 
stated 

in 

the 

list 

of 

the 

technical 

characteristics.  During  emergency  mode,  a 
light source test is also performed.

Resetting Errors 

Place the test card A-1900  on the side of the 
indications  (page  4)  and  remove  it  after  the 
reset  is  conducted  (the  indications  light  in 
sequence),  to  delete  all  the  indicated  LED 
errors.  Then  the  luminaire  enters  regular

 

operation mode.

Indication  LED  status  (with  connected 
mains power supply).

Charge 

On:

 

Good charge current.

Οff:

 

No battery 

(

No charging current 

or disconnected battery

).

Lamp Fault 

(with L1 connected to L)

Οn

 

(with  LED  strip  off)

:

 

Faulty  LED  strip 

(must be replaced).

Οn

 (with LED strip on)

:

 

Problem in the back 

up  circuit  of  the  LED  strip  (must  be  checked 
by an authorized personnel).

Off:

 

 Good LED strip.

Battery Fault

 

Ο

ff

:

 

Battery OK. 

Blink

  (

With  Charge  LED  ON):

  Autonomy  or 

low  battery  problem 

(the  battery  must  be 

replaced).

Blink

 

(

With  Charge  LED  Off): 

No  charging 

current or disconnected battery

.

 

ΑΤΤΕΝΤΙΟΝ

!!!

1. Operations for installation, maintainance or 
testing must be done by authorized personnel 
only, after a mains interruption

.

2. 

The  device  must  be  connected  to  the 

m a i n s   p o w e r   s u p p l y   t h r o u g h   a   f u s e  
dependent  on  the  total  amount  of  the  line’s   
power load

.

3. 

In  case  of  battery  or  lamp  replacement, 

these must be replaced by parts of the same 
type, by the manufacturer or by a competent 
person.

                

4. In case of inactive use for a period greater 
than  2  months,  disconnect  the  batteries  by 
pulling out the battery’s connectors.

 

5

I

s  not  allowed  to  discard  batteries 

t  i

into  common  trash  bins,  they  must 
b e   d i s c a r d e d   o n l y  

 

i n   b a t t e r y  

recycling points. Do not incinerate.

INSTALLATION

To install the luminaire follow the installation 
instructions below.

NOTE: 

LED= Light Emitting Diode

LABELING EXPLANATION:
X: 

Self contained 

  

1:  

Maintained (*)

A: 

Including test device

G: 

Internally illuminated 

 

90: 

1.5 hour duration

180: 

3 hour duration

(*) 

Maintained operation:

 The luminaire lights 

its illumination source, when it is powered by 
the mains power supply or not

.  

 

Non Maintained operation: The luminaire 
lights its illumination source, only in  power 
supply’s failure.

The light source contained in this 
luminaire shall only be replaced by the 
manufacturer, or his agent, or a similar 

qualified person.

NOTE! The light source is non-user 
replaceable.

INSTALLATION INSTRUCTIONS

  

1.

 Remove the front cover by unscrewing the retaining screws

.

 Remove the acrylic plate.

2.

 

Always use in any case round mains cable

,

 with a diameter

 

of 12

-

14mm (H05RN-F type 

4x1mm² 

or 

any 

other type

,

 

at least 

equal 

to it’s mechanical and electrical properties). 

ATTENTION!! The cable must not be deformed in any way (This requirement is important 
to ensure the tightness isolation IP66). 

Pass the round cable through

 

the cable gland and  

tighten it all the way.

3. 

Unfasten the screw to remove the plastic cap (photo1) and connect the battery

s cable as 

shown in the photo 2. Replace the plastic cap and fasten the retaining screw.

4. 

Connect the mains cables as shown in figures 5 and 6. Yellow wire to GND

,  

blue to N

brown 

to L and black for maintained operation

The black wire can be connected to an external switch 

to control the maintained or non maintained operation of the luminaire

For permanent 

maintained operation use three wires to power the luminaire, G

Ν

D for ground N

 

for neutral, L for 

live wire and link the brown and black wire to the same terminal.

5.

 Refit the acrylic plates and the front cover by srewing the removed screws in step 1.

6.

 Power on the device

.

Page

 

3 from

 

4

5

6

N
L

External 

switch

Controlled maintained operation 

Link

Permanent maintained operation 

L1

L

N

N
L

L1

L

N

L1

L

N

4  

74 cm

64,5 cm

40 cm

46,5 cm

1

8

,5

c

m

cable gland 

1  

1  

130m

70m

TYPICAL SYMBOLS

Except  for  typical  symbols  all  luminaires  can  be  constructed  after  request  with 
any other symbols.

Escape routes

Escape exit

Emergency phone

3  

Photo 2

Photo 1

923

579

00

0

_09_0

04

923

579

00

0

_09_0

04