220-240V AC/50-60Hz
3
h
24 h
IP
3
0
3
.
6V/
1
Ah
3
W / 3
.5
VA
EN 60598-1, EN 60598-2-22
, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
o
5 to 40 C
up to 95%
Bayblend FR3010
,
transparent
polycarbonate
49
5gr.
292 x 111 x 54 mm
40lm / 100lm
12 White LEDs
92321
1
00
2
_09_004
Page
1 from
3
‘’
SLIM CLASSIC LIGHT ‘’ SERIES FOR NON MAINTAINED / MAINTAINED
(OPTIONAL) EMERGENCY LUMINAIRES
GENERAL
o
These luminaires are used indoors
(
ta 40 C
)
where emergency light is needed.
E a c h l u m i n a i r e m u s t b e p e r m a n e n t l y
connected to mains power supply
.
In normal
operation the illumination LEDs are lit as well
as the green indicating charge LEDs when
the battery is charging.
In case of a mains power supply failure the
luminaire will light the led strip automatically
in emergency mode. When the mains power
supply is restored the device turns to normal
operation.
Non Maintained / maintained operation
t h e r e i s a n o p t i o n t o s e l e c t t h e n o n
maintained or maintained operation by
placing the jumper to the appropriate place
according to the figure 3 (page 2)
.
INSTALLATION
To install the luminaire follow the installation
instructions on page 2.
ΑΤΤΕΝΤΙΟΝ
!!!
1. Operations for installation, maintainance or
testing must be done by authorized personel
only
.
2.
The device must be connected to the
m a i n s p o w e r s u p p l y t h r o u g h a f u s e
dependent by the total amount of the line’s
power load
.
3.
It is suggested to check every month the
indication LED for battery charging, and by
pushing the TEST button to check the
emergency circuit. The led strip should light as
long as the TEST button is pressed.
If the
luminaire doesn’t work as described above
contact the installer.
4.
It is suggested to check every 6 months the
m i n i m u m a u t o n o n o u s d u r a t i o n b y
disconnecting the mains power supply
.
Count
the time that the led strip lights and in case of
less time than the minimum autonomous
duration the battery must be replaced. If the
measured time is considerably less than the
minimum autonomous duration
contact the
installer.
In case of battery or led strip
replacement, these must be replaced by parts
of the same type,
by the manufacturer or
by a
competent person.
5.
In case of inactive use for a period greater
than 2 months, disconnect the battery by
pulling out the battery’s connector.
6.
I s not allowed to discard batteries in to
t i
c o m m o n t r a s h b i n s , t h e y m u s t b e
discarded only
in battery recycling
points.
Do not incinerate.
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
EXTERNAL DIMENSIONS
CONSTRUCTION MATERIALS
TYPICAL WEIGHT
GUARANTEE
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERIES (Ni-Cd)
CHARGING TIME
INDICATIONS
-
CONTROLS
MINIMUM AUTONOMOUS DURATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
ILLUMINATION
(230V AC
/ emergency)
ILLUMINATION SOURCE
Battery charge indication LEDs
,
TEST button
3 years
(1
year for the battery
)
GR-21
1
0
Thank you for your trust in our products.
Olympia Electronics - European manufacturer
.
TECHNICAL CHARACTERISTICS
(for LED MODULE Specifications see page 3)