220-240V AC/50-60Hz

3

 h

24 h

IP 

3

0

3

.

6V/

1

Ah

3

W / 3

.5

VA

EN 60598-1, EN 60598-2-22

, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3

o

5 to 40  C

up to 95% 

Bayblend FR3010

transparent

 

polycarbonate

49

5gr.

292 x 111 x 54 mm

  40lm / 100lm

  12 White LEDs

92321

1

00

2

_09_004

Page

 

1 from

 3

 ‘’ 

SLIM CLASSIC LIGHT ‘’ SERIES FOR NON MAINTAINED / MAINTAINED

(OPTIONAL) EMERGENCY LUMINAIRES

GENERAL

o

These  luminaires  are  used  indoors 

(

ta  40 C

)

 

where emergency light is needed.
E a c h   l u m i n a i r e   m u s t   b e   p e r m a n e n t l y  
connected  to  mains  power  supply

.

  In  normal 

operation the illumination LEDs are lit as well 
as  the  green  indicating  charge  LEDs  when 
the battery is charging. 
In  case  of  a  mains  power  supply  failure  the 
luminaire  will light the led strip automatically 
in  emergency  mode.  When  the  mains  power 
supply is restored the device turns to normal 
operation.

Non  Maintained  /  maintained  operation 

t h e r e   i s   a n   o p t i o n   t o   s e l e c t   t h e   n o n  
maintained  or  maintained  operation  by 
placing  the  jumper  to  the  appropriate  place 
according to the figure 3 (page 2)

.

INSTALLATION

To  install  the  luminaire  follow  the  installation 
instructions on page 2.

ΑΤΤΕΝΤΙΟΝ

!!!

1. Operations for installation, maintainance or 
testing must be done by authorized personel 
only

.

2. 

The  device  must  be  connected  to  the 

m a i n s   p o w e r   s u p p l y   t h r o u g h   a   f u s e  
dependent  by  the  total  amount  of  the  line’s   
power load

.

3. 

It  is  suggested  to  check  every  month  the 

indication  LED  for  battery  charging,  and  by 
pushing  the  TEST  button  to  check  the 
emergency circuit. The led strip should light as 
long  as  the  TEST  button  is  pressed.

  If  the 

luminaire  doesn’t  work  as  described  above 
contact the installer.

 

4. 

It is suggested to check every 6 months the 

m i n i m u m   a u t o n o n o u s   d u r a t i o n   b y  
disconnecting  the  mains  power  supply

Count 

the time that  the led strip lights and in case of 
less  time  than  the  minimum  autonomous 
duration  the  battery  must  be  replaced.  If  the 
measured  time  is  considerably  less  than  the 
minimum  autonomous  duration 

contact  the 

installer.

  In  case  of  battery  or  led  strip 

replacement, these must be replaced by parts 
of the same type,

 by the manufacturer or 

by a 

competent person.

5. 

In case of inactive use for a period greater 

than  2  months,  disconnect  the  battery  by 
pulling out the battery’s connector.

 

6. 

I s not allowed to discard batteries in to 

t i

c o m m o n   t r a s h   b i n s ,   t h e y   m u s t   b e  

discarded  only 

 

in  battery  recycling 

points.

 

Do not incinerate.

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

EXTERNAL DIMENSIONS 

CONSTRUCTION MATERIALS 

TYPICAL WEIGHT

GUARANTEE 

OPERATION VOLTAGE

MAXIMUM POWER CONSUMPTION
BATTERIES (Ni-Cd)

CHARGING TIME

INDICATIONS 

CONTROLS

MINIMUM AUTONOMOUS DURATION

DEGREES OF COVER PROTECTION

PRODUCED IN ACCORDANCE WITH

ILLUMINATION

 

(230V AC

 

/ emergency) 

ILLUMINATION SOURCE 

Battery charge indication LEDs

TEST button

3 years 

(1 

year for the battery

)

 GR-21

1

0

Thank you for your trust in our products.  

Olympia Electronics -  European manufacturer

.

TECHNICAL CHARACTERISTICS

 