These  luminaires  are  used  in  places  where 
emergency luminaires are needed. 
E a c h   l u m i n a i r e   m u s t   b e   p e r m a n e n t l y  
connected to mains power supply

.

In  normal  operation  (L1  connected  to  L)  the 
led strip lights and the battery is charging.
In    case    of    a    mains    power    supply  failure   
t h e   l u m i n a i r e   w i l l n   l i g h t   t h e   l e d   s t r i p  
automatically in emergency mode (powered by 
its  battery).    When  the    mains    power    supply   
is    restored  the  device  turns  to  normal 
operation. 

INSTALLATION

To  install  the  luminaire  follow  the  installation 
instructions on page 3.

Battery Charging

The  battery  charging  is  completely  controlled

.

 

Thereby, 

the 

best 

possible 

battery 

maintenance  is

 

achieved

as  well  as  the 

elongation  of  its  duration

When  the  battery 

has  completely  charged

it  charges  with  a 

maintenance current.

Battery Cut-off

The  luminaire  enters  in  this  operation  when 
the  mains  power  supply  fails

 

and  battery  has 

lost  its  energy

During  this  operation  the 

luminaire  enters  the  idle  state

 

and  battery 

consumption  is  negligible,  in  order  to  be 
protected from deep discharge.

Manual

 Test

This test can be done by placing the test card 
on  the  side  of  the  indications  (page  4)    and 
remove  it  instantly  an  operation  test  is 
initiated.  The  light  source  and  the  emergency 
circuit of the device is monitored. The manual 
test  can  be  conducted  only  if  the  main  power 
supply  and  the  battery  is  connected.  During 
this test period all indication LEDs are OFF. 

 

Automatic operational test

This  test  includes  all  the  operations  that 
provide  the  manual  test  and  is  conducted 
automatically  every  15  days.  In  order  to  be 
performed,  the  mains  power  supply  and  the 
battery should be connected. 

Automatic Autonomous Test

The Automatic Autonomous Test  is  conducted 
and  measures  the  device’s  back  up  operation 
and  emergency  duration.  This  test  is 
conducted  automatically  every  6  months

In 

order  to  be  performed,  the  mains  power 

 WATERPROOF SELF TESTING MAINTAINED EMERGENCY LUMINAIRES WITH WHITE LEDs

220-240V AC/50-60Hz

4.5W / 4.9VA

TECHNICAL CHARACTERISTICS

 

(for LED MODULE Specs see page 4)

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

EXTERNAL DIMENSIONS 

CONSTRUCTION MATERIALS 

TYPICAL WEIGHT

GUARANTEE 

OPERATION VOLTAGE

MAXIMUM POWER CONSUMPTION
BATTERY

 (

Ni-Cd

)

CHARGING TIME

INDICATIONS

BATTERY PROTECTION

MINIMUM AUTONOMOUS DURATION

DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH

ILLUMINATION (MAINS / EMERGENCY)

ILLUMINATION SOURCE 

90min

24h

Charge, Lamp Fault, Battery Fault LED

From overcharge and deep discharge

IP 65

3.6V/3Ah

  210lm / 210lm 

  30 white LEDs 

EN 60598-1, EN 60598-2-22

, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3

5 to 40  C

o

Up to 95% 

3 years 

(1 

year for the battery

)

745gr.

3.4W / 3.8VA

3.6V/

0.6

Ah

  105lm / 105lm 

  15 white LEDs 

180min

5.3W / 5.6VA

3.3W / 3.7VA

3.6V/1.5Ah

  105lm / 105lm 

  30 white LEDs 

  210lm / 210lm 

  15 white LEDs 

595gr.

675gr.

3

13

 

x 118 x 66 mm

Bayblend FR3010

transparent 

 

polycarbonate