LED MODULE CHARACTERISTICS

Olympia Electronics S.A

.

Cable connection between main pcb and led module

8.7-10.8VDC

0.59W

2801101

 

GR-

151-3

/L

45 °C max. across the board

INSTALLATION INSTRUCTIONS

1  

Detach the plastic base (located in the bottom of the luminaire) by pulling the unlock hook and 

    pass the cables from area     or     and through the cable entry hole.

 

The luminaire must be

    connected to a permanent electrical installation

 to ensure

 the 

immobilization of the cable.

 Mount 

    the plastic base with the included mounting accessories

2

 

 

Connect the mains cables to the respective detachable terminal block

Ν 

for neutral

L for live   

    

wire

.

3  

Attach the luminaire by sliding it on the plastic base until the plastic hook locks, and power the  

    

Luminaire

MAINTAINED TO NON MAINTAINED SELECTION CAPABILITY

4  

Power on the luminaire and press continuously the TEST button for 10 seconds, until the battery     

    charging LED blinks and the led strip turns off. The luminaire operates now as non maintained 
    luminaire. If you want to restore the previous condition (maintained operation), press 
    continuously the TEST button for 10 seconds, until the battery charging LED blinks and the led 
    strip lights with less luminosity.

NOTE!! After finishing the installation you must power the device at least for 24 hours for battery charging to perform the nominal 
autonomy.