Page
2
from
7
3. Adjusting the lower temperature level for
controlling the speed of the fan.
The display shows the message
(
Low
Fan
Temperature
)
,
by pressing the
MENU
button the
factory default setting will appear which is
55
ºC
.
With this setting we can adjust the temperature of
the water from which the fan will gradually starts to
decrease its speed. The value can be set from
50
ºC to (4) decreased by 1. For example if
t h e t e m p e r a t u r e i s
6 5
º C
,
t h e n t h e
temperature can be adjusted from
50-64
ºC
.
The decrease in the fan speed is done gradually
until the (4) temperature is achieved and
finally the fan will stop.
4.
Adjusting the higher temperature level for
controlling the speed of the fan.
The display shows
(
High
Fan
Temperature
)
,
by pressing the
MENU
button, the factory default
setting will appear which is 72ºC
.
With this
arrangement we can choose the water
temperature above which the fan will stop
operating, since the rotation speed
starts to
decrease when
it
start
s
to bec
o
me greater than
the value
(3) and regulated by the
temperature
increased by 1 up to 85
ºC
.
The
automatic fan speed adjustment is done between
the lower temperature and the
temperature .
If these two temperatures
and are adjusted as to have a
difference of only 1°C then the fan operates in
ON/OFF mode.
5. Flame sustentation setting
The display shows the message
(
FiL
Temperature
)
by pressing the
MENU
button, the
factory default setting will appear which is
35
ºC
.
With this setting we adjust the water temperature
below which (if there is not a command from the
room thermostat) the fan will turn in maintenance
state. In this state the screen shows , the
buzzer sounds for 3 minutes, the fan speed is
lowered to the value increased by 15 units
and follows an activation/diactivation cycle
depending on the values and in order to
sustain the flame for as long as possible. If the
water temperature becomes greater than this
value or there is a command from the room
thermostat, then the unit enters normal operation.
This value can be adjusted from 10 to 50 °C
.
6.
Adjusting the maximum fan speed.
The screen shows the message
(
Speed
High) by pressing the
MENU
button the factory
default setting will appear is 100%
.
With this
setting we select the maximum speed of the fan in
order to adjust to the needs of different types of
wood burners. The adjustment value can be set
from +1 to 100%
.
During the adjustment
process the fan changes speed accordingly.
7. Adjusting the minimum fan speed
The display shows (Speed Low). By pressing
the
MENU
button, the factory default setting will
appear which is 30%. With this adjustment we
determine the minimum speed that the fan can
turn.
To determine this speed select 10% and wait until
the fan stops. Gradually increase the value until
the fan starts to rotate.
This value is different for every type of fan and in
conjunction with the define it’s operation
range. The value can be adjusted from
10%
t
ο
5
0%
.
8.
Adjusting the activation time of the fan
during the flame sustentation mode.
The display shows the message
(
Time on).
By pressing the
MENU
button, the factory default
setting will appear which is 1 minute.
With this
setting we can adjust the activation time of the fan
when the unit is in flame sustentation mode
.
If the
value
``
0΄΄
,
is selected the fan will remain
permanently deactivated during the flame
sustentation mode
.
The value can be adjusted
between 0 and 250 minutes.
9.
Adjusting the deactivation time of the fan
during the flame sustentation mode.
The display shows the message
(
Time off).
By pressing the
MENU
button, the factory default
setting will appear which is 10 minutes
.
With this
setting we select the deactivation time of the fan
when the unit is in flame sustentation mode. The
setting can have values from 1 to 250 minutes
.
10.
Fumes Sensor Select
.
The display shows the message
(
Fumes
Sensor Select). By pressing the
MENU
button, the
factory default setting will appear which is .
The value can be set between and
,
and
specifies whether the smoke sensor
will be
active
or not. If
has
the
value
the
parameters 11,
12, 13 have no meaning and therefore can not be
changed by the controller.
11.
Fumes Temperature Adjustment
.
The display shows the message
(
Fumes
Ε
ffect Temperature). Pressing the
MENU
button
will show the factory default setting which is
150ºC.
Th
is
value can be set from 100
°C to
400
°C
and defines the temperature
that the exhaust
should have to achieve the highest possible
performance
of the wood burner
.
The fan’s speed
fluctuates to stabilize the temperature. The
process of regulating the exhaust temperature is
performed only if the parameter value or the
value
is outside of their limiting action.
12. Exhaust temperature adjustment
deactivation time.
The display shows the message
(
Fumes
940844002_09_00
4