background image

81.3

27.3

 

121.5

Dimensions in mm

Dimensions in mm

105

19

Mounting hole spacings

COMMUNICATION ERROR

Errors  can  occur  if  for  any  reason  the 
communication between the two devices is 
disrupted. The screen of the thermostat will 
show  the  message          (Communication 
Error), the backlight of the screen will blink.
The  interruption  of  the  mains  voltage 
causes  the  interruption  of  communication 
between the two devices. When the voltage 
is restored, the peripheral  device-receiver 
activates the outputs according to the state  
before  the  interruption,  until  the 
communication  is  automatically  restored 
with  the  thermostat  (maximum  delay  of  6 
minutes),  so  the  outputs  will  change 
according to the new commands that will be 
given. 

Page 9 from 11

940821001_09_001

80mm

120mm

120mm

34mm

105

19

Mounting hole spacings

Summary of Contents for BS-818/T

Page 1: ...BATTERYOPERATEDWIRELESSPROGRAMMABLECHRONO THERMOSTAT WITHCOOLINGANDHEATINGFUNCTION BOILEROUTPUT BATTERYOPERATEDWIRELESSPROGRAMMABLECHRONO THERMOSTAT WITHCOOLINGANDHEATINGFUNCTION BOILEROUTPUT Thank you for your trust in our products Olympia Electronics European manufacturer 8 7 6 5 4 3 2 1 CONTROL AND INDICATOR DESCRIPTION Thermostat activation Thermostat deactivation Increase value Decrease value...

Page 2: ...aily programming example page 7 Weekly programming example page 8 Wireless communication settings page 8 communication errors page 9 Hour and message display Temperature and message display Temperature units display Active burner output display Selecting on not the area presence program Escape from a selection Activate Deactivate boiler valid only for the BS 819 T Go to the next item or selection ...

Page 3: ...essed simultaneously for 3 first the key and then the the screen will show the message and the keypad is locked Page 3 from 11 GENERAL When the plastic battery separator is remove the unit is automatically activated and shows all the screen indicators for 1 then the firmware version is shown and finally the screen enters final operation status In the center of the screen we can see the current tem...

Page 4: ...nce the end time is the start time of the next program For example if we require a temperature of 23 0 ºC from 14 00 to18 00 in program 1 we will set the start time 14 00 at 23 0 ºC and the start time of the second program 18 00 with the required temperature The 24 hour time base starts at 00 00 and ends at 23 59 The start time of the next program must also be bigger than the start time of the pre...

Page 5: ... With this setting we can turn off the screen illumination in order to conserve battery energy If ΟΝ is selected then the screen illumination will be activated every time a key is pressed If is selected then the screen illumination will be deactivated The factory default is D LED BURNER OUTPUT INDICATOR This setting can deactivate the burner output indicator in order to conserve battery energy If ...

Page 6: ...perate The battery life time has been design to be approximately 2 years Factors that influence the battery life are prolong use of the keyboard with the backlight active increased temperature and humidity as well as battery quality 12 ANTI ICE PROTECTION If the room temperature in which the thermostat is installed falls below 5 C the unit activates the burner output irrelevant of the ON or OFF st...

Page 7: ...e blinking 4 Press the key and the starts to blink With the keys and we select the operation mode Day daily program 5 Press the key and we return to the previous screen with the blinking 6 Press the key 8 times and the screen shows with the blinking Now we are in the daily programming sub menu that has a 10 program capability 7 Press the key and the screen shows with the blinking this shows that w...

Page 8: ...g the key The weekly program will start to execute as defined In order for the program to execute correctly make sure you have programmed the device clock with the correct time WIRELESS CONNECTION SETTING This procedure is required for every new installation in order to establish the communication and to verify the quality of the signal After installing the peripheral received BS 821 R the key mar...

Page 9: ... blink The interruption of the mains voltage causes the interruption of communication between the two devices When the voltage is restored the peripheral device receiver activates the outputs according to the state before the interruption until the communication is automatically restored with the thermostat maximum delay of 6 minutes so the outputs will change according to the new commands that wi...

Page 10: ...sure and the device is ready to operate Fig 4 POWER STATUS indicator N L 230V Boiler indicator Programming button ΒΤ1 Boiler BS 821 R Burner Fig 5 A B Burner indicator To install the BS 821 R remove the front cover with a screwdriver Fig 4 Mark and drill the mounting holes according to the schematic in page 10 Mount the device using the supplied mounting accessories Holes A and B as shown in Fig 5...

Page 11: ...eturned goods and to or not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R Thessaloniki Katerini P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics gr info olympia electronics gr TECHNICAL CHARACTERISTICS BATTERIES 2 Alkaline ΑΑ BS 818 T BS 819 T BS 821 R MODEL...

Reviews: