background image

921655004, 921657002, 921660004_

0

8

_00

6

921655004, 921657002, 921660004_

0

8

_00

6

4

5

1mA for

 2 

sec

90

μ

A

12mA (with activated on board LED

)

0

.

107 

dB/m

0

.

107 

dB/m

-

-

-

Α1

R

Α1

R

EN 54-7

EN 54-7, EN 54-

5

EN 54-

5

Up to

 95%

ABS/PC

158 gr.

158 gr.

143 gr.

years

103 x 48mm

103 x 48mm

103 x 55mm

ο

-40

 

to

 70 

C

ο

57 

C

ο

57 

C

IP42

17-30V DC

Place  the  detector  carefully 

so  that  the  side  marks  are  aligned  and  rotate

  the  detector 

clockwise until it locks. 

Provide power to the device and after

 3-5 seconds it is ready for 

operation.

4

Mounting Base

Connection
with external
LED

5

5

R

+

-R

U

T

/

O

N

  I

+

N

  -

   

I

T

U

-  

   

O

-R

U

T

/

O

N

  I

+

N

  -

   

I

T

U

-  

   

O

Fr o m t he z o ne

of t he p a ne l

term

inal

resis

tor

-R

U

T

/

O

N

  I

+

N

  -

   

I

T

U

-  

   

O

CONNECTION

Connect the power cables (minding the correct polarity) according to the requirements of 
the installation.

1. + IN/OUT :

 It is connected to the zone of the panel or to the (

+ IN/OUT

)

 

contact of 

the previous detector.

2. -   IN : 

It is connected to the zone of the panel or to the (

- OUT

) contact of the

 

previous detector.

3. -   OUT :

 It is connected to the next detector (

- IN

) or if it is the last one to the terminal

 

resistor.

4. -  R :

 It is connected with BS-572.

5.

       

:

 

Connected to the cable’s shield (when shield is used).

Connection

If the power of the detectors is turned off, wait for 3-5 seconds before you turn the power on 
again.

3

4

Warranty

Olympia Electronics guarantees the quality, condition and operation of the goods. The period of 
warranty  is  specified  in  the  official  catalogue  of  Olympia  Electronics  and  also  in  the  technical 
leaflet,  which  accompanies  each  product.  This  warranty  ceases  to  exist  if  the  buyer  does  not 
follow the technical instructions included in official documents given by Olympia Electronics or if 
the  buyer  modifies  the  goods  provided  or  has  any  repairs  or  re-setting  done  by  a  third  party, 
unless Olympia Electronics has fully agreed to them in writing. 

Products that have been damaged 

can  be  returned  to  the  premises  of  our  company  for  repair  or  replacement,  as  long  as  the 
warranty period is valid.

Olympia Electronics  reserves  the  right  to  repair or  to  replace the  returned  goods  and  to  or  not

 

charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to 
charge or not the buyer the transportation cost.

72

nd

 

km

O

.

N

.

R

Thessaloniki-Katerini

P.C. 60300 P.O. Box 06 Εginio Pierias Greece

www.olympia-electronics.com

[email protected]

OPERATION VOLTAGE
START UP POWER CONSUMPTION
STANDBY CONSUMPTION

ALARM CONSUMPTION

SMOKE CONCENTRATION SENSITIVITY

CLASS

OUTPUT

INDICATORS

DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH

OPERATING TEMPERATURE RANGE

RELATIVE HUMIDITY

CONSTRUCTION MATERIALS

TYPICAL WEIGHT

GUARANTEE

TEMPERATURE SENSITIVITY

EXTERNAL DIMENSIONS(     x height)

Alarm LED

To panel / to external LED (BS-572)

Olympia Electronics - European manufacturer

Thank you for your trust in our products  

European

manufacturers

SMOKE DETECTORS  &

RATE OR RISE HEAT DETECTORS

1293

21

BS-

6

55/A

Optical smoke detector

EN 54-

7

:2018

DoP: 9216

55004

_59_002

1922

23

BS-

6

60/A

Rate-of-rise heat detector
ΕΝ 54-5:20

17

+Α1:20

18

DoP: 921660

004

_59_004

1293

21

BS-

6

57/A

Optical smoke & rate-of-rise heat detector
ΕΝ 54-5:2017+Α1:2018 , ΕΝ 54-7:2018

DoP: 9216

5

7

00

2_59_002

EGINIO
PIERIAS
60300 
GREECE

Technical Characteristics

CONSTRUCTION COLOR

WHITE

ANTHRACITE

 (

/C)

TYPE

O

ptical 

smoke detector

O

ptical 

smoke & rate-of-rise 

heat detector

R

ate-of-rise 

heat detector

BS-655/A
BS-655/A/C

BS-657/A
BS-657/A/C

BS-660/A
BS-660/A/C

Reviews: