921655004, 921657002, 921660004_
0
8
_00
6
921655004, 921657002, 921660004_
0
8
_00
6
4
5
1mA for
2
sec
90
μ
A
12mA (with activated on board LED
)
0
.
107
dB/m
0
.
107
dB/m
-
-
-
Α1
R
Α1
R
EN 54-7
EN 54-7, EN 54-
5
EN 54-
5
Up to
95%
ABS/PC
158 gr.
158 gr.
143 gr.
2
years
103 x 48mm
103 x 48mm
103 x 55mm
ο
-40
to
70
C
ο
57
C
ο
57
C
IP42
17-30V DC
Place the detector carefully
so that the side marks are aligned and rotate
the detector
clockwise until it locks.
Provide power to the device and after
3-5 seconds it is ready for
operation.
4
Mounting Base
Connection
with external
LED
5
5
R
+
-R
U
T
/
O
N
I
+
N
-
I
T
U
-
O
-R
U
T
/
O
N
I
+
N
-
I
T
U
-
O
Fr o m t he z o ne
of t he p a ne l
term
inal
resis
tor
-R
U
T
/
O
N
I
+
N
-
I
T
U
-
O
CONNECTION
Connect the power cables (minding the correct polarity) according to the requirements of
the installation.
1. + IN/OUT :
It is connected to the zone of the panel or to the (
+ IN/OUT
)
contact of
the previous detector.
2. - IN :
It is connected to the zone of the panel or to the (
- OUT
) contact of the
previous detector.
3. - OUT :
It is connected to the next detector (
- IN
) or if it is the last one to the terminal
resistor.
4. - R :
It is connected with BS-572.
5.
:
Connected to the cable’s shield (when shield is used).
Connection
If the power of the detectors is turned off, wait for 3-5 seconds before you turn the power on
again.
3
4
Warranty
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of
warranty is specified in the official catalogue of Olympia Electronics and also in the technical
leaflet, which accompanies each product. This warranty ceases to exist if the buyer does not
follow the technical instructions included in official documents given by Olympia Electronics or if
the buyer modifies the goods provided or has any repairs or re-setting done by a third party,
unless Olympia Electronics has fully agreed to them in writing.
Products that have been damaged
can be returned to the premises of our company for repair or replacement, as long as the
warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not
charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to
charge or not the buyer the transportation cost.
72
nd
km
.
O
.
N
.
R
.
Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.com
OPERATION VOLTAGE
START UP POWER CONSUMPTION
STANDBY CONSUMPTION
ALARM CONSUMPTION
SMOKE CONCENTRATION SENSITIVITY
CLASS
OUTPUT
INDICATORS
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATING TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
TYPICAL WEIGHT
GUARANTEE
TEMPERATURE SENSITIVITY
EXTERNAL DIMENSIONS( x height)
Alarm LED
To panel / to external LED (BS-572)
Olympia Electronics - European manufacturer
Thank you for your trust in our products
European
manufacturers
SMOKE DETECTORS &
RATE OR RISE HEAT DETECTORS
1293
21
BS-
6
55/A
Optical smoke detector
EN 54-
7
:2018
DoP: 9216
55004
_59_002
1922
23
BS-
6
60/A
Rate-of-rise heat detector
ΕΝ 54-5:20
17
+Α1:20
18
DoP: 921660
004
_59_004
1293
21
BS-
6
57/A
Optical smoke & rate-of-rise heat detector
ΕΝ 54-5:2017+Α1:2018 , ΕΝ 54-7:2018
DoP: 9216
5
7
00
2_59_002
EGINIO
PIERIAS
60300
GREECE
Technical Characteristics
CONSTRUCTION COLOR
WHITE
ANTHRACITE
(
/C)
TYPE
O
ptical
smoke detector
O
ptical
smoke & rate-of-rise
heat detector
R
ate-of-rise
heat detector
BS-655/A
BS-655/A/C
BS-657/A
BS-657/A/C
BS-660/A
BS-660/A/C