The  BS-506  is  a  battery  operated  smoke  detector  with  an  optical  sensor  for 
installation in residential buildings, apartments and rooms. Smoke

 

alarms

 

are 

designed  to  provide  an  early  warning  of  fire  events  giving  enough  time  for 
people  to  evacuate  the  building/room.  Always  consult  local  regulations  for 
smoke alarms.

Ÿ

Do not paint or cover the smoke alarm.

Ÿ

Consult the manufacturer's advice if the device doesn't work properly.

If  the  battery's  level  is  low,  the  horn  will  sound  as  a  short  pulse  every  43 
seconds  which  continues  until  the  batteries  are  replaced.  If  a  low  battery 
condition  exists,  a  Low  Battery  Hush  mode  can  be  selected  by  pressing  the 
TEST  button,  the  Red  LED  will  turn  on  to  indicate  the  low  battery  condition. 
After the TEST button is released, the unit enters Low Battery Hush mode and 
the  device  is  silenced  for  8  hours.  At  the  end  of  the  8  hours,  the  audible 
indication will resume. The activation of the TEST button will also initiate the 9 
minutes Hush mode.

Ÿ

To  prevent  injury,  the  device  must  be  securely  attached  to  the  ceiling  in 
accordance with the installation instructions.

Ÿ

Do not install the detector close to ventilation points.

CAUTION!!

Ÿ

Do not install the detector in leisure accommodation vehicles

Ÿ

Do not install the detector in direct sunlight. Keep at least 0.5m from light 
sources.

A Device Test is performed when the TEST button is pressed for more than 1 
second. If the device works properly it will produce a loud alarm sound. When 
the TEST button is released, the alarm sound will stop and the device enters 
the  Hush  mode.  After    a  time  of  9  minutes  returns  to  normal  (stand  by) 
operation.

When the device is in Alarm condition, every Device Test will initiate the Hush 
mode. When Hush mode is started, the unit immediately resets out of Alarm 
condition and the horn is silenced. The Hush mode duration is 9 minutes and 
the Red LED flashes faster, after this period expires, the unit goes back to its 
normal operation. During Hush mode, the device's sensitivity is reduced and a 
higher Smoke concentration is needed, to place the unit again into an Alarm 
condition.  Also,  Hush  mode  can  be  canceled  from  the  user  by  performing  a 
new Device Test.

HUSH

LOW BATTERY MODE

Ÿ

Due to the loudness of the alarm, make sure that you always stand at arm's 
length distance from the unit when you are testing.

DEVICE TEST

Ÿ

Batteries  should  be  protected  from  excessive  heat,  such  as  direct  light 
beams or fire.

The  Alarm  Memory  allows  easy  identification  of  any  unit  that  had  previously 
been  in  Alarm.  When  a  detector  exits  an  Alarm  condition,  the  Yellow  LED 
flashes  three  times  and  this  pattern  repeats  every  43  seconds.  This  visual 
indication  will  stop  after  a  period  of  24  hours.  The  user  will  still  be  able  to 
identify a unit that had previously been in Alarm, by pressing the TEST button, 
the horn will sound in short pulses and the Alarm memory resets. The initial 24 
hour visual indication is not displayed when a low battery condition exists.

ALARM MEMORY

When  the  smoke  alarm  is  not  functioning  properly,  it  will  turn  into  the  Fault 
warning mode and produces three short acoustic signals every 43 seconds. Try 
cleaning the smoke alarm (see paragraph maintenance) otherwise replace it!

FAULT WARNING

Test  the  smoke  alarm  weekly  for  correct  operation  using  the  Device  Test 

facility. If the smoke alarm functions correctly, it will generate a loud beep 
otherwise must be replaced immediately! 

Clean the smoke alarm once per month to remove dirt, dust or debris.

Use a vacuum cleaner with a soft brush and vacuum all sides and covers of 

the smoke alarm. Do not remove the top cover of the smoke alarm to clean 
it inside.

In  accordance  with  EN14604  standard,  is  recommended  to  replace  the 

device after 10 years of operation.

Do  not  attempt  to  repair  this  smoke  alarm.  If  the  smoke  alarm  shows  a 

damage it must be replaced!

1
2
1
1

Smoke detector
AA Batteries (installed)
Mounting accessories
Manual

Package Contents

Maintenance

General

Installation instructions

1

2

3

1

5

6

2

3

6 mm

If  no  sound  is  generated,  the  smoke  alarm  is  not  functioning  properly  and 
should not be used!

NOTE!!!

921506000_09_005

921506000_09_005

921506000_09_005

B

C

A

B

C

A

4

Reviews: