MG ON / MG OFF.

 Disable the internal magnetic sensor. It is useful when 

the device 

co-operates only

 with external magnetic contacts.

DEL  /  INS

DEL

  ensures 

that  there  are 

delays 

in 

input  and  output  for  installed

 

detectors at the entrance of a building. The 

INS

 allows the detector to directly cause 

the triggering of an alarm if the control panel is armed. This 

DIP-

switch 

(DEL/INS)

 

has effect only if the scanner has been programmed in a 

natural reaction

 from the 

control panel (zone with delay 

or 

zone without delay). 

ATTENTION!!

 

When

 zone with delay

 is 

select

ed

, it is 

necessary

 the setting of the 

BS-468/A

 to be done

.

The device can be connected to external magnetic contacts via the CN2 terminal

 

block

 (Figure 3). If a magnetic field is connected to this input, the device sends an 

alarm  signal  to  the 

control 

panel.

  If

  the  contact  is  not  connected  to  an  external 

device, at the 

cable 

terminal

 

of the CN2, the

n

 manufacturer

’s cable

 must remain.

N

OTE:

The maximum distance of the external sensor cable is 3 meters !!!

Figure 2

Front panel device (side view)

Alignment marks

Installation should only be carried out by 

qualified

 technicians. The device 

is activated

 when 

it 

is moved away from

 the magnet. The main device must be installed in the stationary part of 

the  window  or  door  and  the  magnet  in  the  moving  part.  The  detector  must  be  installed 
vertically

.  It  is  forbidden  to  be  installed 

inside  a  metal  frame  (it  prevents  wireless 

communication).

 Its use is not 

reliabl

e

 on an iron door or an iron

 

window. 

To install, follow the procedure below:
1.

 Open the lid of the device.

2.

 Secure the back plastic to the stationary part of the window or door.

3.

 Attach the magnet to the moving part. The distance from the device must be

 

a

    

maximum of 5mm when the door / window is closed. The 

bottom

 of the magnet

    must be aligned with the 

bottom

 of the device (Figure 1). T

he

 magnet may be located

    either 

to the left or 

to the 

right of the device,

 but please pay attention to the alignment

    marks 

(Figure 2).

4.

 Unplug the battery and 

let 

the lid open, 

set

 the panel to 

ins

tallation

 mode

 of

 

wireless

    

devices (see the manual of the table)

.

5.

 Insert the battery into the device and close the lid.

6.

 

Please,

 note that the device has revers

e

 

installation 

protection

 for 

the battery.

 CN2

Figure 3.

Example of con

nection 

NC 

external 

magnetic contacts

with

 

BS-471

Once the device is connected to the panel's network, remove the battery and wait for 
10 seconds. Then press the 

tamper

 and re

install

 the battery. Wait until the 

LED 

lights 

up. Once you release the 

t

amper, the 

LED

 will go out. In this case, the range

 test

 will 

start.

 

During 

range test

 the device LED 

blink

s every second. The duration of 

range 

TEST is 60-95 seconds. When it is finished the LED 

goes off 

and after 2 seconds the

 

test

 result 

is displayed

 as follows:

Single

 

blink

:

 

Strong signal.

 The device can be 

safely installed 

at this point.

Two 

blink

s:

 

Normal signal.

 The device can be safely 

installed

 at this point.

Three 

blink

s:

 

W

eak signal.

 It is 

recommended

 not to 

install

 the device 

at this point.

                                             T

he

re will be communication bettween the device and

                                             the control panel 

but there will

 

be communication

                                             

packet

s losses

.

Four 

blink

s:

 

Out of range.

 The 

device

 is forbidden to be placed in th

is point

.

Note

!!

 As soon as the TEST procedure is started, it is suggested that the 

device 

c

over

 

will 

be placed directly in order to simulate the actual communication conditions. The 

environment must be also

 

adapted to the worst possible conditions (eg closed doors).

 

Finally, in case of 

home improvements or renovation

, it is suggested 

to perform a

 

range 

TEST

 

again

.

INSTALLATION

INSTALLATION

DIP SWITCH

ES

DIP SWITCH

ES

CONNECTION WITH EXTERNAL MAGNETIC

 CONTACTS

CONNECTION WITH EXTERNAL MAGNETIC CONTACTS

RANGE TEST

RANGE TEST