background image

Unscrew the holding screw and gently raise the front cover.
Carefully unscrew the PCB holding screw located on the PC board.
Break out the desired knockout holes for proper installation.
The circular and rectangular indentations at the bottom base are the knockout holes for wire entry. 

You may also use mounting holes that are not in use for running the wiring into the detector.
For bracket mounting option - lead wire through the bracket.
Mount the detector base to the wall, corner or ceiling (For option with bracket see Fig. 4).
Reinstall the PC board by fully tightening the holding screw. Connect wire to terminal block.
Replace the cover by inserting it back in the appropriate closing pins and screw in the holding
screw.

Connections

Connect to terminal 1 (-) and 2 (+) the power supply

.

Connect to the terminals 

and

 4 

the wires from the zone

 24Η (

24 hours zone

).

The  6  and  7  terminals  are  the  detector’s  alarm  output

Connect  to  these  terminals  the  wires  of  the 

panel’s detection zone

.

Testing the detector 

Apply 12 Vdc power to the detector, wait 2 minutes to finish the detector warm up time. Conduct 
testing with the protected area cleared of all people.
Remove front cover.Make sure that 

PIR and MW 

switches are in positions high sensitivity.

Make sure that 

LED 

switch is 

ON.

Replace the front cover.
Start walking slowly across the detection zone.
Observe that the detector's LED lights whenever motion is detected.
Allow 5 sec. between each test.
After the walk test is completed, the 

LED, PIR and MW 

switches may be changed.

NOTE: 

Walk tests should be conducted, at least once a year, to confirm proper operation and 

coverage of the detector.