INTRODUCTION

The Olson Technology OTOT-1000 is a higher performance indoor wideband laser transmitter with an RF passband
of 48 to 1,000MHz. The OTOT-1000 also offers enhanced CATV performance. These transmitters are intended for
indoor applications. They combine the transmitter and universal AC power supply in one compact housing that has a
footprint of 7.5" x 5.5" x 1.6". The optical output power and bandwidth of each transmitter is as follows:

OTOT-1000-3

+3dBm, 48-1,000MHz

OTOT-1000-6

+6dBm, 48-1,000MHz

OTOT-1000-8

+8dBm, 48-1,000MHz

OTOT-1000-9

+9dBm, 48-1,000MHz

OTOT-1000-10

+10dBm, 48-1,000MHz

OTOT-1000-12

+12dBm, 48-1,000MHz

OTOT-1000-13

+13dBm, 48-1,000MHz

OTOT-1000-14

+14dBm, 48-1,000MHz

OTOT-1000-15

+15dBm, 48-1,000MHz

Each transmitter has a universal power supply and will operate from 90 to 240V

AC

 at 50 or 60 Hz and consumes about

10 Watts.

The OTOT-1000 is an ideal forward signal source for the OTPN-1000 High Sensitivity Indoor Node and will allow
for an optical path loss of 21 dB or more. Test points are provided for laser output power and current to allow for
historical review of operating parameters. An RF test point is provided to allow proper setup and for historical review.

Positive cooling is provided by means of a small, high-MTBF fan, which may be replaced in the field without interrupting
the operation of the unit.

The OTOT-1000 has flanges on the bottom to allow mounting it to a flat surface. The available OTLL-RMKIT-1 will
allow mounting up to three of these units in a standard 19" rack.

INSTALLATION / ENVIRONMENTAL CONSIDERATIONS

The OTOT-1000 transmitters are specified to operate from -10°C to +55°C. They usually do not require an air-
conditioned environment. They should be mounted in an adequately ventilated area. Like all electronic equipment, it
will generally have a longer life span if it is not operated at the upper limit of the temperature range. Installation in wet
areas or areas of extremely high humidity should be avoided. Extremely dirty or dusty areas should be avoided if
possible. Objects or debris should not be allowed to block the openings in the housing or the fan. The unit should not
be installed in areas that are accessible to children.

The OTOT-1000 may be installed and operated in any position on a flat surface. The unit has four slots in the bottom
plate to accommodate mounting hardware. If mounting requires a wood screw, use #6 or #8 (maximum) pan-head
sheet metal screws. These are commonly available at hardware stores. If mounting with a machine screw (to tapped
holes), use 6-32 pan-head screws.

Summary of Contents for OTOT-1000

Page 1: ...COSTOPTICALTRANSMITTERS 1 000 MHz BANDWIDTH OPTICAL OUTPUT POWER FROM 3dBm OTOT 1000 3 to 15dBm OTOT 1000 15 INSTRUCTION MANUAL 025 000554REVX7 09 03 09 209 586 1022 800 545 1022 209 586 1026 E Mail s...

Page 2: ...tallation EnvironmentalConsiderations Page 4 OpticalConnectorsandCleaning Page 5 InternalControls Page 5 External Controls andTest Points Page 6 InitialSetup Page 6 InputDrivevs ChannelLoading Page 7...

Page 3: ...ble parts There is exposed high voltage inside this unit Only factoryservicetechniciansshouldopentheunitwithpowerapplied FIRE HAZARD TheAC line input fuse is contained in the IEC 320 power input conne...

Page 4: ...videdtoallowpropersetupandforhistoricalreview Positivecoolingisprovidedbymeansofasmall high MTBFfan whichmaybereplacedinthefieldwithoutinterrupting theoperationoftheunit TheOTOT 1000hasflangesonthebot...

Page 5: ...epackaged alcohol wipes are the most convenient means of cleaning optical connectors Clean alcohol and lint free wipes or swabs may also be used INTERNAL CONTROLS There are no internal user adjustment...

Page 6: ...t point levels withotherinputconditions INITIALSETUP Mount the unit and apply power The laser is temperature controlled The unit will operate immediately after turn on but requires about 5 minutes to...

Page 7: ...er of equivalent analog channels is 77 42 4 which equals 87 5 This is the 87 5 ch 17 6dBmV input point on the graph Some systems use an OMI meter to set laser modulation The OTOT 870 s OTOT 1000 s hav...

Page 8: ...025 000554REVX7 Page 8 FIGURE 3 INPUT LEVEL vs CHANNEL LOADING HIGH POWER UNITS...

Reviews: