55
Settings “delay”
Display
Action
Description
settings
temp. off
1°C
delay
---
temp drop 2°C
or
If an external room thermostat is connected the de-
lay can be set from 1 to 9 minutes or “---”. Through
this measure the appliance continues to run, after
reaching the preset room temperature by the time
defined in the delay, in order to prevent or ignore fast
temperature changes or fluctuations of the external
room thermostat (e.g. due to brief opening of a win-
dow).
Factory setting: ---
Select the minutes with (ENTER) (the value flashes),
set the value with ↓ or ↑ and confirm with (ENTER).
Information “software”
Display
Action
Description
information
service
op.hours
Ver. 1.00.35 L6
2000h
0h
The software version (Ver.), e.g. 1.00.35 and L6 or
L8 will be displayed:
L6 = 6 kW
L8 = 8 kW
Information “service”
Display
Action
Description
information
service
op.hours
Ver. 1.00.35 L6
2000h
0h
Display for the next service according to operating
hours:
- Count begin: 2000 hours
- next service: 0 hours
Execute service, see chapter “Service”
Information “operating hours”
Display
Action
Description
information
service
op.hours
Ver. 1.00.35 L6
1988h
12h
The operating hours (op.hours) since commission-
ing, e.g. 12 h are shown.