3NB/3ND/3N0/3NK
1-4-25
8930
Center-folding unit backup
error
Read and write data does not
match 3 times in succession.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
CF main PWB (YC7) and DF main PWB
(YC9)
Improper installa-
tion EEPROM.
Check the installation of the EEPROM and
remedy if necessary.
Defective CF main
PWB.
Replace the CF main PWB and check for
correct operation.
Code
Contents
Causes
Check procedures/
corrective measures