background image

PR113500CR installation instructions.pdf

Installation Instructions

Installation Instructions

To the consumer

C

D

E

F

G

Max 37

B

A

Please ensure that the lines are flushed prior to installation as contaminates in the water can damage the 

Ceramic Cartridge, flow regulator and also affect the performance of the Mixer.

Under No Circumstances 

should any abrasive, cream or acid based cleaning agents be used as these 

types of cleaners will damage the finish, Cartridge, seals and aerators.

General Note:

 

This product is to be installed by a licensed plumber,installation must comply with

AS/NZS 3500 and local plumbing codes

°

C

1. The Mixer is to only be cleaned with warm soapy water and a soft cloth.

10. Using Fixing Nut (G) tighten Mixer to mounting Surface.

11. Connect Mixer tails to Mains Water supply line.

12. Ensure the Mixer tails are not Kinked, Bent, stretched or twisted when assembling to the Mains Water 

      Supply. The Mixer Tail connection between the mixer and the Water supply must have a natural curve.
13. Ensure Mixer tails are not exposed to Abrasions, corrosive agents or alike.
14. It is recommended that In-Line filters be installed to ensure a cleaner flow of water to the mixer.

1. Remove product from packaging and check for damages, if the product is damaged do not install and 

    return to store of purchase.

2. The WELS compliant aerator has been pre-assembled into the mixer outlet. To comply with WELS the flow 

     regulator must remain in place.
3. Ensure Product is complete as per exploded drawing.

4. A single 35mm Hole is required in the mounting surface. 

5. The maximum mounting surface thickness cannot exceed 37mm.

6. Ensuring bench sealing washer (A) is in place on base of Mixer Dress ring (B) firmly screw the Mixer tails 

    (C) into base of the Mixer being careful to avoid damage to the o’ring seals, the Mixer tails are colour coded, 

    Red for hot and Blue for cold, the mixer base inlet holes are stamped with ‘H’ for Hot and ‘C’ for cold.

8. Feed the Mixer tails (C) through the Mounting surface, each end alternatively and position the mixer on the 

    mounting surface ensuring the sealing washer (A) is positioned correctly in Mixer dress ring (B).

7. Screw threaded rod (D) into base of Mixer.

9. Slide Rubber Horse Shoe (E) onto threaded rod (D) followed by Metal Horse shoe Plate (F).

    

N.B The Mixer Tails should be positioned towards the user and the Fixing bolt to the back.

2. 

Issue Date 15/02/2019 Revision Number: V1.0

Pressures & Temperatures

Maximum Hydrostatic Pressure – 500 kpa. (As per AS/NZS3500)

Note: AS/NZS 3500.1-2003 (Clause 3.3.4) states that “Provision shall be made to ensure that the 

maximum static pressure at any outlet, other than a fire service outlet, within a building does not 

exceed 500 kPa.

Note: Pressures above 500kPa can cause damage from water hammer, reduced life of appliances, 

taps and fittings, and cause excessive noise in the system.

Minimum Hydrostatic Pressure – 100 kpa

The Maximum operating temperature for the Mixer Tap is 65    .

CRITICAL-TO THE INSTALLING 

PLUMBER

Mixer tails have been pre-

assembled for your convenience.

Please ensure prior to installation 

you pre-check the assembled mixer 

tails to ensure they are firmly 

tightened into the mixer base,and 

re-check the mixer tails after 

connection to the mains water 

supply to ensure the mixer tail 

assembly is water tight.

Braided stainless 

steel flexible hoses 

must be inspected 

every 12 months for 

warning signs of 

failure including

bulging,rust spots,

wear,moisture,

snapped threads,

kinking,water staining,

general corrosion or

discolouration.

Mixer tails showing any 

signs of the above 

mentioned warning 

signs must be replaced 

immediately.

Reviews: