PROBLEM
SOLUTION
Water vapor and humidity are
not produced.
Power plug: Unplug and then try again.
Power Failure: When the power is returned, try again.
Tank Installation: Make sure the tank is correctly attached.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
Air blows but water vapor is not
produced.
Excessive Water: Remove a certain amount of water from the tank.
Detergent residue and/or oil ingredients from cosmetics, etc may be in tank;
wash out tank and try again.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
If you use hard water, replace with softer water.
Humidity level is low.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
The water in the unit is too cold: Replace with cool, but not cold water.
The humidity has a bad smell.
Poor maintenance or dirty water: Clean the product thoroughly, and fill it with
fresh water.
White dust is forming on nearby
furniture.
Hard water may deposit a certain of dust. Dust in the air also settles because
of added humidity in the room. Use distilled water if this becomes a nuisance.
Unit has stopped working.
No or low water. Unplug unit and refill tank.
Water is accumulating outside of
unit or area surrounding unit.
Saturation of humidity. Lower mist control setting.
Unit not level and water is accumulating. Unplug and place on level surface.
Point spray away from objects. Raise unit on a water-resistant level surface at
least 60 cm from the floor.
Water dripping when refilling.
Water remaining on bottom of tank. Wipe tank or tilt to drain before transporting.
Increased noise level.
Unit must be placed on a flat, level, hard surface. Make sure it is NOT placed
on a soft or absorbent surface.
Flashing light symbols.
Indicates low water. Unplug and refill tank.