background image

ENGLISH

EN - 24

 

 

When replacing batteries, replace both and dispose of the dead batteries in the 

appropriate collection centres and as required by law.

  if the remote control is not used for several weeks or longer, remove the batteries. 

 

Any leaks from the batteries could damage the remote control.

 

 

Do not re-charge or disassemble the batteries. Do not throw the batteries into the fire. 

 

They can burn and explode.

 

 

If the battery liquid falls onto the skin or clothes, wash well with clean water. Do 

not use the remote control with batteries that have leaked. 

 

The chemical products contained in the batteries can cause burns or other risks 

to health.

3.3.c - Location of the remote control

  Keep the remote control in a position from which the signal can reach the receiver (24) of the appliance 

(maximum distance is approx. 8 metres - with charged batteries) (figure 28).

  the presence of obstacles (furniture, curtains, walls, etc.) between the remote control and the appliance 

reduces the remote control range.

3.4   USE OF THE APPLIANCE

Work as follows in order to use the appliance.

 

 

To prevent possible damages to the compressor, each start is delayed by 3 minutes 

with respect to the last switching off.

3.4.a  Preliminary operations

•   Place the appliance on a stable and not inclined base, at at least 30 cm. from 

the wall or from any other object, in order to ensure the correct air circulation. 

Place it on a water-resistant surface since the possible water leakage could 

damage furniture or the floor.

•  Do not place the appliance directly on carpets, towels, blankets or other absor-

bent surfaces.

•  Insert the plug in the power socket; the appliance emits a “beep”, on the display 

appears the icon   and the environment temperature in °C.

 

 

Before electrically connecting the appliance, make sure the plate data correspond 

to those of the electricity distribution network.

Summary of Contents for AIR PRO

Page 1: ...EN IT INSTRUCTION FOR USE AND MAINTENANCE ISTRUZIONI PER USO E MANUTENZIONE AIR PRO Caution risk of fire Attenzione rischio di incendio...

Page 2: ......

Page 3: ...sull apparecchio 7 Per il corretto funzionamento dell apparecchio rispettare le distanze minime e le indicazioni riportate nel presente manuale vedere figura 1 8 Per il corretto collegamento elettrico...

Page 4: ......

Page 5: ...1 2 8 5 9 14 15 12 13 11 4 3 6 min 30cm m in 30cm 20 20 min 70cm 1 3 5 2 4...

Page 6: ...2 1 3 4 4 min 2m min 2m 6 2 36 6 8 10 7 9 11...

Page 7: ...4 8 8 9 4 8 9 5 5 12 17...

Page 8: ...27 27a 27 27 27 27a 27 27a 27 18 20 22 23 19 21...

Page 9: ...30 8m 32 32a 30 12 28 28 32 32a 24 28 26 25 29 27...

Page 10: ...32 35 35 30 31 15 27 27 27a 32...

Page 11: ...5 a Use as dehumidifier 20 2 5 b Use as heat pump 20 only for the suitable version 20 SECTION FOR THE TECHNICIAN AND USER 3 USE OF THE APPLIANCE 21 3 1 CONTROL PANEL SYMBOLS AND KEYS Fig B 21 3 2 REMO...

Page 12: ...ice or in the store at which you bought the product This regulation is valid only in EU member states 3 12 OTHER FUNCTIONS 28 3 12 a SILENT function 28 3 12 b SLEEP function 28 3 12 c FOLLOW ME functi...

Page 13: ...hs marked with this symbol contain very important information and recommendations particularly as regards safety Failure to comply with them may result in danger of injury to the operators loss of the...

Page 14: ...esents the risk of burns due to contact with components at very high temperatures Do not cover Indicates to the personnel concerned that it is prohibited to cover the appliance to prevent over heating...

Page 15: ...the manual carefully for future reference 4 After removing the packaging check that the appliance is in perfect condition The packaging materials must not be left within reach of children as they can...

Page 16: ...disconnect the plug from the power socket For repair work contact solely the technical service centres authorised by the manufacturer and ask for original spare parts to be used Failure to do this can...

Page 17: ...on a stable plane and levelled surface 31 Leave at least 30cm of free space on both sides and behind the appliance and leave at least 30cm of free space above it Fig 1 32 Do not place the appliance ne...

Page 18: ...e appliance in case of malfunctioning or faults if the cord or plug are damaged or if it has been dropped or damaged in any manner Turn the appliance off disconnect the plug from the socket and let it...

Page 19: ...very humid environments laundries greenhouses etc or in places with other machines that generate a strong heat source in proximity of a sources of salt water or sulphurous water DO NOT use gas gasoli...

Page 20: ...plianceshallbestoredinaroomwithoutcontinuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater 6 Do not pierce or burn 7 Be aware that the...

Page 21: ...liances The storage of equipment should be in accordance with the manufacturer s instructions 21 Storage of packed unsold equipment Storage package protection should be constructed such that mechanica...

Page 22: ...be displayed g Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work A degree of ventilation shall continu...

Page 23: ...l components the casing is not altered in such a way that the level of protection is affected This shall include damage to cables excessive number of connections terminals not made to original specifi...

Page 24: ...ed from the system or isolated by means of shut off valves in a part of the system remote from the leak Oxygen free nitrogen OFN shall then be purged through the system both before and during the braz...

Page 25: ...rior to re use of reclaimed refrigerant It is essential that electrical power is available before the task is commenced a Become familiar with the equipment and its operation b Isolate system electric...

Page 26: ...er with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants In addition a set of calibrated weighing scales shall be availab...

Page 27: ...6 Terminal for slider window installation 8 Seal for SLIDER installation 9 Seal for SLIDER installation 11 Remote control 12 Condensation discharge pipe dehumidification mode only 13 Terminal adapter...

Page 28: ...nded to check that the wheels are clean and that they can move freely 2 2 WARNINGS A failure to respect what follows may cause damages to the appliance a Install the air conditioner on flat and stable...

Page 29: ...figures 11 and 12 g Apply the adhesive seal 8 Fig 12 h Position the SLIDER KIT 4 and adapt it Fig 12 i Position the flexible hose 1 and apply the seal 9 Fig 12 l If desired position the locking bracke...

Page 30: ...is positioned on a drain well or in a container Make sure the pipe 12 is not clogged c If necessary apply the terminal 13 to the condensation dis charge pipe 12 2 5 b Use as heat pump only for the su...

Page 31: ...rsion with heat pump cooling turbo cooling SW3 Temperature delay increase SW4 Temperature delay decrease SW5 Display SW6 Confirmation cancellationunitswitchingon off delay SW7 Fan speed selection Mini...

Page 32: ...B7 Activate deactivate display on machine control panel B8 Unit switch OFF delay setting B9 Unit programmed switch on setting B10 Short cut B11 Temperature set increase Temperature set decrease B12 Di...

Page 33: ...ference Electronic and fluorescent lights may also interfere with transmissions between remote control and air conditioner Remove the batteries in case of prolonged disuse of the remote control 3 3 a...

Page 34: ...res with charged batteries figure 28 The presence of obstacles furniture curtains walls etc between the remote control and the appliance reduces the remote control range 3 4 USE OF THE APPLIANCE Work...

Page 35: ...not possible to select the fan speed in AUTO mode 3 6 COOLING MODE COOL a When this mode is selected the appliance dehumidifies and cools the environment This mode can be selected by pressing the key...

Page 36: ...the display of the control panel and or of the remote control icon on the control panel icon on the remote control display c In this mode the fan is always switched on and it is possible to select it...

Page 37: ...e control display light up b Once the set time has passed the appliance starts with the same settings mode temperature and ven tilation speed as those before switching off c Time can be set with 30 mi...

Page 38: ...his temperature will be maintained for 7 hours before returning to the originally selected temperature Once this time has passed the appliance will restart working as originally programmed d Press the...

Page 39: ...l and the flap starts oscillating automatically c Press the key SWING to stop the flap in a certain position Press it again to restart oscillation 3 12 f Short Cut function This function can be activa...

Page 40: ...1 c Cleaning the air filter A dirty air filter reduces the cooling capacity of the appliance Please clean the filter once every 2 weeks a Release the grille 27 together with the filter 27a and raise...

Page 41: ...e air conditioner and disconnect the power supply c Clean the air filters d Completely discharge condensation e Wrap the power supply cable 34 around the cable winder 33 and insert the plug in the spe...

Page 42: ...tor temperature sensor error E3 Condenser temperature sensor error E4 Display panel communication error In these cases a electrically disconnect the appliance b wait a few minutes c connect the plug t...

Page 43: ...h off the appliance and clean the filters following the instructions Switch off the appliance disconnect the pipe remove the possible obstruction and reconnect the drain pipe Contact an assistance cen...

Page 44: ...CAP COMPRESSOR BLACK BLUE M BLUE Y G PUMP M M SWING OPTIONAL RED OPTIONAL OPTIONAL CN23 CN25 3 4 5 CN27 P1 UP FCAP DOWN FCAP 2 2 3 4 RY2 HEATER CN26 4 VAVLE P7 RED BLACK BLUE BLACK OPTIONAL OPTIONAL...

Page 45: ...tore 20 2 5 b Utilizzo come pompa di calore 20 solo per il modello predisposto 20 SEZIONE PER IL TECNICO E PER L UTENTE 3 USO DELL APPARECCHIO 21 3 1 SIMBOLI E TASTI PANNELLO COMANDI Fig B 21 3 2 TAST...

Page 46: ...ltimento rifiuti o il negozio in qui stato acquistato il prodotto Questa disposizione valida solamente negli stati membri dell UE 3 12 ALTRE FUNZIONI 28 3 12 a Funzione SILENT silenzioso 28 3 12 b Fun...

Page 47: ...CNICA CLIENTI Indice I paragrafi preceduti da questo simbolo contengono informazioni e prescrizioni molto importanti particolarmente per quanto riguarda la sicurezza Il mancato rispetto pu comportare...

Page 48: ...schio di subire bruciature per contatto con componenti con elevata temperatura Non coprire Segnala al personale interessato che vietato coprire l apparecchio per evitarne il surriscaldamento Attenzion...

Page 49: ...lteriore consultazione 4 Dopo aver tolto l imballaggio assicurarsi dell integrit dell apparecchio gli elementi dell imballaggio non devono essere lasciati alla portata dei bambini in quanto potenziali...

Page 50: ...rente Perl eventualeriparazionerivolgersiesclusivamenteaicentridiassistenzatecnica autorizzati dal costruttore e richiedere l utilizzo di ricambi originali Il mancato rispetto di quanto sopra pu compr...

Page 51: ...rficie stabile piana e livellata 31 Lasciare almeno 30cm di spazio libero sui lati e dietro l apparecchio e lasciare almeno 30cm di spazio libero sopra l apparecchio Fig 1 32 Non collocare l apparecch...

Page 52: ...stato fatto cadere o danneggiato in qualsiasi modo Spegnere l apparecchio scollegare la spina dalla presa di corrente e farlo controllare da personale professionalmente qualificato 49 Non smontare n a...

Page 53: ...avanderie serre ecc o in locali dove sono presenti altri macchinari che generano una forte fonte di calore in prossimit di una fonte di acqua salata o acqua sulfurea NON usare gas benzine o altri liqu...

Page 54: ...a sull apparecchio 5 L apparecchio deve essere immagazzinato in un locale senza la presenza di fonti di accensione a funzionamento continuo per esempio fiamme libere apparecchi funzionanti a gas o ri...

Page 55: ...parecchiatura dispositivi Lo stoccaggio dell apparecchiatura deve essere conforme alle istruzioni del co struttore 21 stoccaggio di apparecchiatura imballata invenduta L imballo deve essere costruito...

Page 56: ...per assicurarsi che non esistano elementi infiammabili o rischi di ignizione Utilizzare segnaletica antifumo g Area ventilata Assicurarsi che l area di installazione sia all aperto o adeguatamente ve...

Page 57: ...attrezzaturadurantelariparazione un dispositivo di rilevamento perdite permanentemente funzionante deve essere posizionato nel punto pi critico per avvisare l operatore di una situazione potenzialment...

Page 58: ...efrigerante e corrodere le tubazioni in rame Se si sospetta una perdita tutte le fiamme libere devono essere rimosse spente Se viene rilevata una perdita di refrigerante la quale necessita di saldatur...

Page 59: ...nenti E considerata buona prassi recuperare tutti i refrigeranti in maniera sicura Prima di eseguire questa operazione prendere un campione di olio e di refrigerante nel caso sia necessaria un analisi...

Page 60: ...valvole d intercettazione perfettamente funzionanti I cilindri di recupero vuoti devono essere messi sotto vuoto e se possibile raffreddati prima del recupero L attrezzatura di recupero deve essere pe...

Page 61: ...ider finestra 8 Coibentante per installazione SLIDER 9 Coibentante per installazione SLIDER 11 Telecomando 12 Tubo scarico condensa modalit sola deumidificazione 13 Terminaleadattatorepertuboscaricoco...

Page 62: ...raccomanda di verificare che le ruote risultino pulite e libere nel loro movi mento 2 2 AVVERTENZE La mancata osservanza di quanto segue pu essere causa di danni all apparec chio a Installare il clim...

Page 63: ...nare lo SLIDER KIT 4 e adattarlo Fig 12 i Posizionare il tubo flessibile 1 e applicare la guarnizione 9 Fig 12 l Se desiderato posizionare la squadretta 5 Fig 12 Estendere il tubo solo per il necessar...

Page 64: ...u un pozzetto di scarico o in un recipiente Assicurarsi che il tubo 12 non sia ostruito c Se necessario applicare il terminale 13 al tubo di scarico condensa 12 2 5 b Utilizzo come pompa di calore sol...

Page 65: ...ddamento raffreddamento turbo SW3 Aumento temperatura ritardo SW4 Riduzione temperatura ritardo SW5 Display SW6 Conferma annullamentoritardoaccensione spegnimento unit SW7 Selezione velocit ventilator...

Page 66: ...ore batteria telecomando scarica D13 Indicatore funzione TIME OFF attiva D14 Indicatore funzione TIME ON attiva D15 Indicatore funzione ECO attiva D16 Segnale trasmissione telecomando B1 Tasto on off...

Page 67: ...erenze Lampade elettroniche e fluorescenti possono interferire nelle trasmissioni tra telecomando e condizionatore Estrarre le batterie di alimentazione nel caso di inutilizzo prolungato del telecoman...

Page 68: ...i con le batterie cariche Fig 28 La presenza di ostacoli mobili tende pareti ecc tra il telecomando e l apparecchio riduce la portata del telecomando 3 4 UTILIZZO DELL APPARECCHIO Per utilizzare l app...

Page 69: ...sul display del telecomando c In modalit AUTO non possibile selezionare la velocit della ventola 3 6 MODALIT RAFFREDDAMENTO COOL a Impostando questa modalit l apparecchio deumidifica e raffredda l amb...

Page 70: ...ita icona si visualizza sul display del pannello comandi e o del telecomando icona sul pannello comandi icona sul display del telecomando c In questa modalit il ventilatore sempre acceso ed possibile...

Page 71: ...postato l apparecchio si avvia con le stesse impostazioni modalit temperatura e velocit di ventilazione che aveva prima di spegnerlo c Il tempo impostabile con step di 30 minuti fino a 10 ore e con st...

Page 72: ...ratura impostata di 1 C 1 o 2 F per altri 30 minuti c Questa temperatura verr mantenuta per 7 ore prima che ritorni alla temperatura originariamente sele zionata Trascorso questo tempo l apparecchio r...

Page 73: ...camente c Per fermare il flap in una certa posizione premere il tasto SWING Premerlo di nuovo per riavviare l oscillazione 3 12 f Funzione Short Cut Questa funzione attivabile solo dal telecomando a Q...

Page 74: ...amente ricambi originali 4 1 c Pulizia del filtro aria Il filtro dell aria sporco riduce la capacit di raffreddamento dell apparecchio Provvedere quindi alla sua pulizia ogni due settimane a Sganciare...

Page 75: ...l alimentazione c Pulire i filtri dell aria d Scaricare completamente l acqua di condensa e Avvolgere il cavo di alimentazione elettrica 34 sull avvolgicavo 33 e inserire la spina nell apposito allog...

Page 76: ...ambiente E2 Errore sensore temperatura evaporatore E3 Errore sensore temperatura condensatore E4 Errore di comunicazione pannello display In questi casi a scollegare elettricamente l apparecchio b att...

Page 77: ...iere gli ostacoli Chiamare il Centro assistenza Spegnere l apparecchio e pulire i filtri se guendo le istruzioni Spegnere l apparecchio scollegare il tubo rimuovere l eventuale ostruzione e ricollega...

Page 78: ...AP COMPRESSOR BLACK BLUE M BLUE Y G PUMP M M SWING OPTIONAL RED OPTIONAL OPTIONAL CN23 CN25 3 4 5 CN27 P1 UP FCAP DOWN FCAP 2 2 3 4 RY2 HEATER CN26 4 VAVLE P7 RED BLACK BLUE BLACK OPTIONAL OPTIONAL OP...

Page 79: ......

Page 80: ...d or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure If you have any queries regarding your product or its warranty please find contacts below...

Reviews: