CAPABILITIES

It can be set to send calls upon all events or 
to selected events

 (

i.e

 

alarm

fault

 

e.t.c

or in 

combination  of  events

  (

i.e.

 

During  an  alarm 

and fault

). 

The programming can be done via 

a BS-466 keyboard or computer.

There is the capability to test the availability 
of the telephone line

This selection must be 

disabled  if  the  telephone  line  is  used  by 
others  telephone  devices  because  it  will 
issue telephone line faults.

INCOMING CALLS

Regarding  calls  toward  the  PSTN  module  it  is 
required  to  enter  one  of  the  2  codes  (user  or 
technician)  in  order  to  retrieve  the  status  of 
the  system.  If  an  action  is  required  (system 
arming)  e.t.c)  then  an  additional  code  is  also 
required.  When  a  call  is  placed  to  the  GSM 
and  the  GSM  module  picks  up  the  line  is  will 
issue  one  beep.  After  the  beep  is  heard  we 
must  enter  the  user  or  technician  code  using 
our  handset  keyboard.

 

If  the  code  is  wrong 

t h e n  3  b e e p s  a r e  h e a r d  a n d  t h e  l i n e  i s 
terminated.  If  the  code  is  correct  then  the 
system  status  message  is  replayed  4  times. 
When  the  messages  finish,  a  beep  is  heard 
and  the  GSM  waits  for  another  code  entry. 
N o w  w e  c a n  e n t e r  t h e  u s e r  c o d e ,  t h e 
te ch n i ci a n  co d e  o r  o n e  o f  th e  5 0  g e n e ra l 
purpose  codes.

     

If  the  code  is  wrong  then  3 

beeps  are  heard  and  the  line  is  terminated.  If 
the  code  is  correct  then  the  action(depending 
on  the  code)  is  executed,  2  beeps  are  heard 
and  the  new  system  status  message  will  be 
replayed  4  times  after  which  the  line  will  be 
terminated.

  

OUTGOING CALLS

During  an  outgoing  call,  when  the  call  is 

answered  there  is  a  beep  sound  and  the 
message  concerning  the  state  of  the  system 
is played for 4 times.

 

If,  for  example  the  system  is  disarmed  and 
there  is  a  fault  then  the  message 

FAULT

D I S A R M E D

” 

w i l l  b e  h e a r d  f o r  4  t i m e s 

whereas if there is an alarm and the system is 
armed the message “

ALARM

ARMED

” 

will be 

heard for 4 times

At the end of the message a 

beep  will  be  heard  and  after  5  seconds  the 
line  will  be  closed.

 

If  during  the  message 

period    any  key  apart  from  the 

“#” 

key  is 

pressed,  on  the  receiving  telephone

then  3 

beeps are heard and the line is closed without 
any other action. If the 

“#” 

key is pressed then 

2  beeps  are  heard,  the  line  is  closed  and  the 
PSTN dialer does not dial any other numbers 
s i n c e  o n e  n u m b e r  h a s  a l r e a d y  b e e n 
informed.  This  is  done  to  prevent  disturbing 
the other numbers.

 

ALARM RECEIVING CENTER 

(

Contact ID)

The 

BS-465 

can  communicate  with  an  alarm 

receiving  center

  (

ARC).  The  communication 

protocol  is  Contact  ID  (CID).  Via  the

 

CID  the 

ARC  is  informed  for  every  event  that  takes 
place on the panel.

To communicate with the ARC, the technician 
must enter 2 elements

:

1) 

The telephone of the ARC center.

2) The panel ID

Please  note  that  the  panel  ID  is  unique  for 
each installation

.

These  elements  are  provided  by  the  ARC 
support company. 

These  elements  are  entered  with  the  help  of 
the BS-466 keyboard.

Specifically  on  BS-466  keypad  we  have  to 
enter  the  technical  menu,  next  the  PSTN 
m e n u 

a n d 

f i n a l l y 

c h o o s e 

S I G N A L S 

RECEIVING CENTER. In the picure below we 
can see all the available oprions.

STATE SRC

In  that  option  we  can  activate/deactivate 
s e n d i n g  s i g n a l s  t o  t h e  S R C  ( S i g n a l s 
Receiving Center).

Figure

 3 : “

Connecting the telephone line”.

92

1465

000_09_0

06

SIGNALS RECEIVING CENTER
STATE SRC
TELEPHONE SRC
ID PANEL, 0-9 & B-F
NOTIFY INCIDENTS
COMMUNICATION CHECK
COMMUNICATION TEST

Summary of Contents for BS-465

Page 1: ...ne and a telephone handset The LINE input is used to connect the telephone line cable Figure 3 The TELEPHONE input is used to connect any other telephone device that we require Page 1 from 4 BS 465 PSTN TELEPHONE DIALER CARD FOR BS 468 PANELS TECHNICAL CHARACTERISTICS OPERATION TEMPERATURE RANGE RELATIVE HUMIDITY EXTERNAL DIMENSIONS WEIGHT GUARANTEE OPERATION VOLTAGE CONSUMPTION INPUTS CALL MODE P...

Page 2: ...nd the message concerning the state of the system is played for 4 times If for example the system is disarmed and there is a fault then the message FAULT DISARMED will be heard for 4 times whereas if there is an alarm and the system is armed the message ALARM ARMED will be heard for 4 times At the end of the message a beep will be heard and after 5 seconds the line will be closed If during the mes...

Page 3: ...informed if the communication test was successful or not CID SIGNALS The BS 468 panel sends the following signal to the ARC with there respective codes 1110 3110 Fire 1120 3120 Panic 1122 3122 Silent Alarm 1130 3130 Alarm 1137 3137 Tamper alarm 1300 3300 Fault 1301 3301 AC power fault 1302 3302 Battery fault 1303 3303 RAM memory fault 1330 3330 Peripheral device fault 1401 3401 Disarm Αrm 1406 Can...

Page 4: ...ovided or has any repairs or re setting done by a third party unless Olympia Electronics has fully agreed to them in writing Products that have been damaged can be returned to the premises of our company for repair or replacement as long as the warranty period is valid Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the ...

Reviews: