165mm
Function Instructions
6
1, Learning method
Press the recognizer's function setting key, the red indicator light turns to blue LED indicator, within 5 seconds, press the tag's setting key, blue indicator
light of recognizer flashes 3 times, learning is successful, up to 200pcs tags can be matched.
2, Delete method
Press and hold the recognizer's setting key, until blue indicator light of recognizer flashes slowly, then release it, blue indicator lights is always on, wait
for the blue lights turns to red lights, all tags will be deleted. (Note: press for 5 seconds, blue light flashes slowly, press for 10 seconds, blue light flashes
quickly)
3, Sensing distance setting
Sensing distance with 3 levels: the 1st level is 1 meter, the 2nd level is 3 meters, the 3rd level is 5 meters. Press and hold the recognizer's setting key,
the tag's indicator light flashes once, twice, three times, once.....form a cycle. When the tag's indicator light flashes once, and release the setting key,
that is in the 1st level. Flash twice means in the 2nd level; flash three times means in the 3rd level.
When the distance between the two adjacent doors is less than 4 meters, the tag sensing invalid and the door
does not open, please try to reduce sensing distance of the tag.
Technical parameters
7
Recognizer
Access authorization: Learning code
The min distance between door and door: 4 meters
The max quantity of the tag: 300pcs
Output signal: COM, NO, Dry contact
Output delay time: 2.5 seconds
Power supply: AC/DC 12~30V
Action current: 229mA
Dimension: 132mm(L)x48.7mm(W)x31(H)mm
Tag
Power supply(701(0)): 3V (CR2032 cell buttons)
Power supply(701C(0)): 5V
Standby current: 10
μ
A
Transmitting current: 2mA
Launch range: Three levels adjustable (1,3,5 meters)
Dimension(701(0)): 46mm(L)x46mm(W)x11mm(H)
Dimension(701C(0)): 58mm(L)x38mm(W)x12mm(H)
Scene two: Plug in and connect by USB port
001
003
002
≥4m
≥4m
Scene one: carry it portably and no need to plug in
001
003
002
≥4m
≥4m
When the person carrying the tag enters the sensing range of
the Door 002, the Door 002 will be opened automatically. The
people stay in the sensing range, Door 002 will always stay
opening until people leave the sensing range.
When the car carrying the tag enters the sensing range of the
Door 002, the Door 002 will be opened automatically. The car
stay in the sensing range, Door 002 will always stay opening
until car leave the sensing range.