12
Specifications
Specifications for the
gas monitor are listed in Table 1-1.
Item
Description
Enclosure
Cast aluminum, poly-bonded coating or 316 stainless steel. Both are
explosion-proof, NEMA 4X, IP66 rated.
Dimensions
5.0 × 6.0 × 5.0 inches (127 x 153 x 129 mm)
Sensors
Combustible Gases: Catalytic bead and/or Non-Dispersive Infrared
(NDIR) Oxygen/Toxic Gases: Electrochemical diffusion
Input Voltage
12-28 VDC operating range (24 VDC typical)
Input Current
(Max)
Toxic Gas/Oxygen
150 mA@24 VDC (single gas)
200 mA@24 VDC (single gas + HART)
Combustible
Gases (Catalytic)
250 mA@24 VDC, 0.8 A peak (single gas)
300 mA@24 VDC, 0.8 A peak (single gas + HART)
Combustible
Gases (Infrared)
170 mA@24 VDC, 0.5 A peak (single gas)
220 mA@24 VDC, 0.5 A peak (single gas + HART)
Combined
Catalytic/Infrared
350 mA@24 VDC, 1.2 A peak (two gas)
400 mA@24 VDC, 1.2 A peak (two gas + HART)
Display
Dual-channel split-screen LED display (4-digit, 7-segment
arrangement per channel) provides simultaneous display of one or
two gases.
Signal
Outputs
Digital
ModBus RTU: RS485 digital communication
with ModBus RTU software protocol system
at 9600 baud. Three- or four-wire system
accommodates over 200 devices in bus
configuration. Address selection through
on-board 8-position DIP switch. NOTE:
ModBus is not to be used for CSA C22.2 No.
152 compliance.
Analog
4-20 mA (linear analog)
Alarm Relays
Quantity
3 alarm relays: Two user-programmable
relays, SPST, N.O.; plus one fault relay,
SPST, N.C.
Contact Capacity
5A @ 30 VDC
5A @ 30 VAC
Temperature
Range
-40 ºC ~ +75 ºC (-40 ºF ~ +167 ºF)
Humidity
Range
10% - 90% RH (non-condensing), typical
Pressure
Atmospheric pressure ±10%
Weight
2.9 Kg (6.4 lbs.)
Table 1-1 Specifications for
the Monitor
Summary of Contents for iTrans 2
Page 6: ...6...
Page 9: ...9...
Page 10: ...10...
Page 19: ...19 Figure 2 5 Electronics Board for Remote Sensor...
Page 20: ...20...
Page 28: ...28 Figure 4 4 Wiring Diagram for a Single On board Sensor...
Page 31: ...31 Figure 4 7 Wiring Remote Sensors Back to...
Page 52: ...52...
Page 60: ...60...
Page 66: ...66...
Page 72: ...72 Figure A 4 Wiring Diagram of Single Sensor HART Supported...
Page 73: ...73 Figure A 5 Wiring Diagram of Dual Sensor HART Supported...
Page 80: ...80 Figure A 15 EDD GUI View Figure A 16 PC to HART Interface Wiring Diagram...
Page 86: ...86...
Page 90: ...90...
Page 98: ...98...
Page 100: ...100...
Page 104: ...104...
Page 105: ...105...