oldfields Treco UTZ1015 Manual Download Page 4

THIS MANUAL WILL BE USED FOR THE FOLLOWING GARDEN SHED MODEL NUMBERS.

MODEL No.

APPROX. ROOF

OVERALL

APPROX. BASE

APPROX. FOUNDATION

DYNABOLT

DIMENSIONS

HEIGHT

DIMENSIONS

DIMENSIONS

6mm x 40mm

ZINCALUME

COLOURBOND

feet

mm

feet

mm

feet

mm

feet

mm

Qty.

• 4 •

A x B

C

D x E

X x Y

INSTALLATION ADVICE

Check the label on the pack to ensure you have the model shed you ordered.
Please retain info on model No. at the end of the carton.

BEFORE YOU START, IT IS IMPORTANT THAT YOU READ THE FOLLOWING INSTRUCTIONS.

When 

selecting a site

, choose an area that is firm and level yet allows drainage away from the site.

Although this shed when installed according to instructions, is designed to withstand greater wind loads than other
conventional sheds, 

do not assemble it in areas subject to high winds or erect on a windy day

. Any building left

partially constructed may be seriously damaged if left in this state. It is your responsibility to safely and securely
anchor the shed, having regard to the windiest conditions in the area. The shed could possibly blow away causing
damage and possible injury if not properly attached to the ground foundation.

Do not backfill

against the walls or base of the shed as this will cause corrosion and void the warranty.

The 

prevention of condensation

inside the shed will assist in keeping the contents dry as well as minimising any

possible corrosion of the shed itself, the following hints may prove useful.

There is always dampness in soil, and this may rise into the shed if there is no barrier. A heavy duty polythene sheet
may be placed under the concrete slab to prevent evaporation into the shed.

Seal the space between the bottom frame and the concrete slab with a mastic (except at the front corners). The front
corners are not sealed to enable drainage out of the ends of the front base rail.

If condensation still presents a problem, panels of polystyrene (5cm thick) may be glued to the interior of the roof
between the supports. Use a glue that is resistant to moisture and temperature.

You will need a few tools

, as indicated in the section HOW TO READ THIS MANUAL. 

Most holes for screws are

predrilled

. A power screw driver or cordless drill equipped with a magnetic Philips tip will hasten assembly. Take care

not to over-tighten self-tapping screws.

Sort, separate and identify all parts and hardware before construction. Check against the illustrations shown. Framing
components are labelled.

Since this manual is used to instruct assembly of varying sizes of shed, 

Labelling of Parts

in the diagrams has been

simplified as follows:
All the frame work components have the same system of part numbers but indicate different lengths, these part
numbers are stamped into the component.

e.g. Roof Beams

9 foot length = 

P9

7 foot length = 

P7

5 foot length = 

P5

Therefore, in the diagrams the Roof Beam is labelled 

P

.

IMPORTANT SAFETY FEATURES

Observe all special notes which indicate differences between various types of sheds.

You should not try to assemble the shed on your own. Get a second person to help you.

The statutory requirements of the local building authorities must be observed.

Safety gloves should be worn during assembly.

Safety glasses should be worn during assembly.

Preferably in a long sleeve shirt.

Beware of sharp edges.

WINTER SERVICE: The roof  is designed for a snow load of 75 kg/m2. In order to avoid overload of the roof, timely
removal of snow from the roof area is recommended.
If the garden shed is unattended for lengthy periods during the winter months, the roofs should be propped up as a
safety precaution.

THE MANUFACTURERS CANNOT BE HELD RESPONSIBLE FOR ANY CONSEQUENCES DUE TO SHEDS THAT ARE
NOT ERECTED PER INSTRUCTIONS OR FOR DAMAGE DUE TO WEATHER CONDITIONS OR ACTS OF GOD. PARTS
MAY CONTAIN SHARP EDGES & CORNERS. CARE MUST BE TAKEN WHEN HANDLING VARIOUS PIECES TO AVOID A
MISHAP, FOR SAFETY SAKE, PLEASE USE A PAIR OF WORK GLOVES & EYE PROTECTION WHEN ASSEMBLING OR
PERFORMING ANY MAINTENANCE ON THE BUILDING.

Note:

All dimensions are approximate. All dimensions in mm. 1 Foot = 30.48cm. Dynabolts are NOT supplied.

FG = Federation Green, IH = White and W = Wheat assembly is the same as Zincalume.
PLEASE REFER TO SEPERATE PARTS LIST FOR FG, W AND IH.

UTZ1015

UTASC1015

10´ x 15´

3070 x 4650

79.92”

2030

9´8´ x 14´8´´

2960 x 4540

10´ x 15’

3070 x 4700

27

UTZ10152

UTASC10152

10´ x 15´

3070 x 4650

88.58”

2250

9´8´ x 14´8´´

2960 x 4540

10´ x 15’

3070 x 4700

27

UTZ1019

UTASC1019

10´ x 19´

3070 x 5880

79.92”

2030

9´8´ x 18´8´´

2960 x 5780

10´ x 19’

3070 x 5900

29

UTZ10192

UTASC10192

10´ x 19´

3070 x 5880

88.58”

2250

9´8´ x 18´8´´

2960 x 5780

10´ x 19’

3070 x 5900

29

Summary of Contents for UTZ1015

Page 1: ...TY UTASC1015 UTZ1015 UTASC1019 UTZ1019 UTASC10152 UTZ10152 UTASC1019S UTZ10192 ENGLISH NEDERLANDS FRAN AIS DEUTSCH ESPA OL SWEDISH ALLTRECO PRODUCTS ARE MANUFACTUREDTO COMPLYWITH ALL AUSTRALIAN STANDA...

Page 2: ...TS AVANT DE DEBUTER LA CONSTRUCTION AIDEZ VOUS DES ILLUSTRATIONS V R MET DE OPBOUW TE BEGINNEN MOETEN ALLE ONDERDELEN EN BOUWELEMENTEN GESORTEERD GESCHEIDEN EN GE DENTIFICEERD WORDEN ZIE OOK DE ILLUST...

Page 3: ...outen niet bijgevoegd 6 Combinatietang 7 Punt van de schroevedraaier Philips No 2 8 Ijzerzaag Outils n cessaires Rem arque Tous les outils mentionn s sont n cessaries pour monter l abri de jardin Ces...

Page 4: ...magnetic Philips tip will hasten assembly Take care not to over tighten self tapping screws Sort separate and identify all parts and hardware before construction Check against the illustrations shown...

Page 5: ...le Einzelteile und Beschl ge aussortieren auseinanderhalten und kennzeichnen Vergleichen Sie sie mit den Illustrationen in diesem Handbuch Die Rahmenteile ausgenommen die Paneele sind gekennzeichnet v...

Page 6: ...n op de onderdelen gestempeld Dakbalken bijvoorbeeld 9 voet lang P9 7 voet lang P7 5 voet lang P5 De dakbalken zijn daarom met P aangegeven in het diagram BELANGRIJKE VEILIGHEIDSMAATREGELEN Let op all...

Page 7: ...t simplifi comme suit Tous les l ments de la charpente portent le m me num ro de pi ce qui montre toutefois diff rentes longueurs ces num ros de pi ces sont estampill s sur l l ment Par exemple Poutre...

Page 8: ...aci n de partes pero indican diferentes largos los n meros de las partes est n estampados en los componentes Por ej Vigas del Techo 9 pies de largo P9 7 pies de largo P7 5 pies de largo P5 Por lo tant...

Page 9: ...s tt Alla komponenter i ramen har samma delnummersystem men visar olika l ngder Dessa delnummer r inst mplade p komponenten i fr ga t ex taksparrar 9 fot l nga P9 7 fot l nga P7 5 fot l nga P5 I diagr...

Page 10: ...e d tanch it Vis auto taraudeuses Vis Tek utiliser pour porte de devant uniquement Boulon 3 16 Equerre entre portique et poutrelle de toit Pignon Poutrelle de toiture support D angle gousset de base d...

Page 11: ...11 HARDWARE KIT BAG X8 X10 X11 X15 X15A1 X28 X34 X20 PB2 X20UT X20G X26 HA01002A HA01000A HA01001A TR010074A X25 Pack A Model Model Pack B Pack C D Pack E Pack...

Page 12: ...ss frame HD5UT T5 T6 Roof edge trim K Wall Panel HDX1 Door Panel C1750 C1970 C1300 Door panel trim O1 Pack B Panneau d angle arri re Panneau final de toiture Panneau Plaque de verrou cadenas Fourche C...

Page 13: ...Mid wall brace PF2 Portal Frame Rafter PF3 Portal Frame Sealing Strip PF4 PF Bottom Chord Panneau Colonne du cadre de portique Rainure sup rieure inf rieure arri re Sup rieure poutrelle de base avant...

Page 14: ...cadre de portique MODELS UTASC1019 UTASC10192 UTZ1019 UTZ10192 K K K K F K K K F K K K K K K K K K AVF4 AVF4 D O O R P O R T E P O R T E P O R T E P O R T E D O O R K K K K K K K K K K K K K K F K K K...

Page 15: ...his additional warranty is subject to the following qualifications and limitations 1 The warranty Certificate attached must be completed and returned to Treco within 21 days of purchase 2 Warranty onl...

Page 16: ...16 Door 100mm C D E E Y D X Door 100 mm...

Page 17: ...l A1UT these holes required for anchoring the shed to foundation at next step Avant de commencer l installation percer 14 trous de 7 mm de diam tre le long des deux bords plats de la pi ce Rainure ch...

Reviews: