Technical Specifications

The following technical indications are medial values. During operation small variations are
quite possible.

2.1

Control Unit

Dimensions (L x W x H)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 x 12 x 22 cm

Weight

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . about 0,9 kg

Voltage

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 VDC

Operating Temperature

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0

‰

– 50

‰

Storage Temperature

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20

‰

– 60

‰

Air Humidity

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5% – 75%

Waterproof

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

No

Table 1: Technical Specification (Control Unit)

2.2

Laser Pointer

Laser Class

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 (according to EN 60 825-1)

Range

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to 50 m

Wave Length

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 630 – 680 nm

Maximum Output

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

<

1 mW

Table 2: Technical Specification (Laser Pointer)

OKM Ortungstechnik GmbH

www.okm-gmbh.de

Summary of Contents for FS Future Series

Page 1: ...FS Future Serie FS Thermoscan 8 User s manual ...

Page 2: ...circumstances OKM takes responsibility for lost profits usage or data losts interruption of business activities or all kind of other indirectly damages which developed because of errors in this documentation This instruction manual and all other stored media which are delivered with this package should only be used for this product Program copies are allowed only for security and savety purposes T...

Page 3: ...ment Readings 7 3 Scope of Delivery 8 4 Controls 9 4 1 Complete View 9 4 2 Front View 10 5 Usage 11 5 1 Calibration 11 5 2 Usage as stand alone device 12 5 3 Usage as optional equipment to eXp 4000 13 5 3 1 Thermograph 14 5 3 2 Thermo Scan 15 6 Maintenance and Services 17 OKM Ortungstechnik GmbH www okm gmbh de ...

Page 4: ...a measurement on the hillside 13 7 The operating modes Thermograph and Thermo Scan of eXp 4000 13 8 The Operating Mode Thermograph On The eXp 4000 14 9 Measurement with eXp 4000 and connected FS Thermoscan 15 List of Tables 1 Technical Specification Control Unit 6 2 Technical Specification Laser Pointer 6 3 Technical Specification Measurement Readings 7 4 Scope Of Delivery 8 OKM Ortungstechnik Gmb...

Page 5: ... of mineralisation and the dimensions of an object relating to its depth Specially in very wet soil clay and sand with high conductivity of the ground recording of the measured results can be falsified strongly With this product you purchased a device which stood the tests in regular operation like all other products of us If you are interested in where our devices have gone into action please vis...

Page 6: ...L x W x H 35 x 12 x 22 cm Weight about 0 9 kg Voltage 12 VDC Operating Temperature 0 50 Storage Temperature 20 60 Air Humidity 5 75 Waterproof No Table 1 Technical Specification Control Unit 2 2 Laser Pointer Laser Class 2 according to EN 60 825 1 Range up to 50 m Wave Length 630 680 nm Maximum Output 1 mW Table 2 Technical Specification Laser Pointer OKM Ortungstechnik GmbH www okm gmbh de ...

Page 7: ... Temperature 10 25 Distance Spot Size Ratio 8 1 Field Of View Flare Angle 7 Resolution 0 01 Temperature Difference min amplification 9 Temperature Difference max amplification 1 Table 3 Technical Specification Measurement Readings OKM Ortungstechnik GmbH www okm gmbh de ...

Page 8: ...ic equipment 1 FS Thermoscan Control Unit 1 External Power Supply 1 Charger For External Power Supply 1 Adapter For External Power Supply 1 User Manual 1 Carrying Case Table 4 Scope Of Delivery Beware that pictures in this manual could be different to delivered parts FS Thermoscan Control Unit External Power Supply Charger For External Power Supply Adapter for External Power Supply Figure 1 Scope ...

Page 9: ...the device during the measurement On the Analog Display all measured values are visible The Laser Pointer marks the position of the recording of the measured value if activated With the Connecting Plug to External Power Supply Or eXp 4000 you can connect the device to an eXp 4000 or via the Adapter Cable to an external battery You have the possibility to use the device as a stand alone unit withou...

Page 10: ...ts help it is possible to do accurate measurements Via the Analog Display the current measure value is represented The deflection of this display depends on the adjustment of the calibration and the sensitivity Further information about the calibration of the FS Thermoscan you can find in section 5 1 on page 11 By using the Regulator Of Calibration you can adjust the indicator of the analog displa...

Page 11: ...s process areas with subterranean caves tunnels or boxes achieve faster the balance of temperature with the surrounding atmosphere Thereby a cold zone arise on the surface of the ground on this position where the cavity is situated under the ground Figure 4 Schema of the thermal distribution of cavities In thermographs graphical representation of the thermal distribution which has been done during...

Page 12: ...rea the larger the sensibility should be Only in this way small variations in temperature can be visible If you are using the FS Thermoscan out of the adviced temperature of the surface it can happen that the indicator of the Analog Display cannot be calibrated to the center of the display 5 2 Usage as stand alone device Connect the FS Thermoscan via the Adapter Cable with the 12V plug socket of t...

Page 13: ...ng the FS Thermoscan as a stand alone unit it can also be used as an optional equip ment to the eXp 4000 If the FS Thermoscan is used together with the eXp 4000 there are additional possibilities of graphical analysis besides the Analog Display So a more accurate survey of the area is possible Figure 7 The operating modes Thermograph and Thermo Scan of eXp 4000 As soon as you connect the FS Thermo...

Page 14: ...tor is subdivided in 3 parts Digital Display In the Digital display on the upper left part of the monitor the analog measuring values of the FS Thermoscan are represented in a digital form Because of the higher resolution of this display also smallest variations of the temperature becomes visible Snap Shot The snap shot on the right side of the monitor shows the current increasing or decreasing me...

Page 15: ...you like to do a calibration If you confirm this question by Yes you will enter into the operating mode Thermograph There you have the possibility to calibrate the FS Thermoscan via the Analog Display or the digital display of the eXp 4000 After you finished the calibration of the device press the button Previous Operating Mode Arrow Up or the button Next Operating Mode Arrow Down to go back to th...

Page 16: ...o it is possible to inspect rock faces hillside situations or similiar structures After proceeding the measurement the graphic can be stored transfered onto a computer and analysed in the software All functions of the software are usable but please note that a depth measurement is not possible in this operating mode The differences in temperature are only measured on the surface of the ground and ...

Page 17: ...r device please use a dry rag of soft material To avoid any damage you should transport the device and accessories always in the appropriate carrying cases Beware that all batteries and accumulators are always charged fully while operating with your system You should only load the batteries when they are completely discharged no matter if you are working with the external power supply or with the ...

Page 18: ...000 13 14 External Power Supply 12 FS Thermoscan 14 Handhold 9 Laser Pointer 9 16 Next Operating Mode 15 Power On And Off Button For Laser Pointer 10 Previous Operating Mode 15 Regulator Of Calibration 10 12 Regulator Of Sensibility 10 12 Temperature Sensor 15 16 Thermograph 15 Digital Display 14 Snap Shot 14 15 Trend Chart 14 18 ...

Reviews: