22. Carefully remove the drum.
23. You are now ready to remove the PCR.
24. Remove the PCR by un-clipping it from
the white and black holders.
25. Remove the wiper blade by unscrewing the two gold-colored screws at each end that
hold it in place as shown.
26. Lift the wiper blade evenly from the
waste hopper.
28. Use air pressure to blow out any
remaining toner.
27. You are now ready to clean the wiper
blade and waste hopper.
29. Once clean, you are now ready to
reassemble t he wiper blade.