______________________________________________________________________
- 16 -
www.OKIUSA.com
IR INT LEVEL TABLE
NOTE1:
*1: AGC LEVEL
*2: IR INT LEVEL (ACT UP THE LEVEL)
*3: SENSE UP
NOTE2: IR INT LEVEL (MAX) Approach 15Lux (illumination)
IR INT LEVEL (MIN) Approach 0.02Lux (illumination)
Press ENTER key to enter IR SW FUNCTION menu.
Press UP or DOWN key to select IR SW detection EXT.
IR SW will be set manual mode.
IR SW EXT. MENU
Press UP or DOWN key to select IR EXT LEVEL MAX
or MIN.
IR EXT LEVEL MAX: IR CUT OFF (B/W MODE)
IR EXT LEVEL MIN: IR CUT ON (COLOR MODE)
IR EXT LEVEL MENU
OFF
x 2
x 4
x 6
x 8
x 12
x 16
x 32
x 64
BASE
x x MAX
16 15 14 13 11 9
+1 x MAX
15 14 13 12 11 9 7
+2 x 16 14 13 12 11 10 8 6
+3 x 15 13 12 11 10 9 7 5
+4 MAX
14 12
11
10
9 8 6 4
+5 16 13 11
10
9 8 7 5 3
+6 15 12 10
9 8 7 6 4 2
+7 14 11 9 8 7 6 5 3 1
MAX
13 10 8 7 6 5 4 2 MIN
IR SW
IR SW
→
EXT.
IR EXT LEVEL
IR INT LEVEL
→
MAX
*3
*2
*1