OKIUSA 03/06
①
. FAR/NEAR
②
. WIDE/TELE
③
. DC LEVEL
The VR for adjusting the IRIS level of Auto Iris Lens.
④
. SWITCHES
(1). AES/OFF
AES : Automatic Electronic Shutter. The range of
shutter speed from 1/60sec. (1/50sec.) to 1/100,000
sec.. This mode is employed for using a manual iris
lens.
OFF : AES OFF. The shutter speed is 1/60sec.
(1/50sec.).
When an auto iris lens is applied, AES should
be off.
(2). BLC/OFF
BLC : Backlight Compensation. When the object is
dark by strong light (sunlight etc….) as (Fig.2-1),
please turn on BLC.
OFF : BLC OFF.
(3). AGC/OFF
AGC : Automatic Gain Control.
The level of gain
Varies from 0 to 26dB.
OFF : AGC OFF. The level of gain is fixed at 0dB.
(4). FL/NOM
FL : Flickerless. In FL mode, the shutter speed is
1/100sec. (NTSC system) / 1/120sec. (PAL ).
If choose FL mode, [AES] switch should be off.
NOM : Normal position.
NOMENCLATURES AND FUNCTIONS
①
CAMERA MOUNTING
Drill 20mm(3/4") hole on the ceiling as installation
template. (see Fig.1).
②
③
④
Fix the mounting plate onto the ceiling as installation
template shown holes position. (see Fig.2).
Fix the dome camera body onto the mounting plate.
(see Fig.3).
The
on bottom of dome camera body should
be put in the same way on mounting plate then turn right to
make sure it is fixed properly.
Adjust PAN/TILT position and FAR/NEAR &
WIDE/TELE bar to get the mounting picture. (see Fig.4).
Put the cover on to finish the installation. (see Fig.5).