background image

7 - English

Material Safety Data Sheet 
(MSDS N° 58376901)

Series Drum/Toner Cartridge 
52124803 

For more information, contact Oki Data at: 2000 Bishops 
Gate Boulevard, Mount Laurel, NJ 08054-4620.
Emergency Information (US and Canada only): call 
1-800-654-3282.

Emergency First Aid Procedures

Toner swallowed (ingested).

Rinse out mouth with water and give several glasses of 
water to drink. Seek medical attention. 

Toner inhaled.

Remove person to fresh air. Rinse mouth with water.

Toner gets in the eyes.

Flush eyes with large quantities of cool water for 15 
minutes, keeping the eyelids open with fingers. Seek 
medical attention.

Toner gets on the skin.

Wash toner off the skin with plenty of cool water and soap.

Note: Small amounts of toner on skin or clothing can 

easily be removed with soap and cold water. 

Hot water makes toner harder to remove.

Hazardous Ingredients

Polyester (40-50% by weight)

CAS#: Not available
OSHA PEL: Not available.

Iron Oxide (40-50% by weight)

CAS#: 1309-38-2
OSHA PEL: Not available.

Amorphous Silica (1-5% by weight)

CAS#: Not available
OSHA PEL: Not available.

Ethylene/Propylene Copolymer (<5% by 
weight)

CAS#: Not available
OSHA PEL: Not available.

Titanium Dioxide (<1% by weight)

CAS#: Not available
OSHA PEL: Not available.

Physical Data

Physical State: Solid
Melting/Freezing Point: Not available
Boiling Point: Not applicable
pH: Not available.
Vapor Pressure: Not applicable
Vapor Density (Air=1): Not applicable
Evaporation Rate (Butyl Acetate=1): Not available
Specific Gravity (H

2

O=1): Not available

Solubility in Water: Negligible
Solubility in Solvents: Not available
Coefficient of Water/Oil Distribution: Not available
Appearance and Odor: Black powder, faint odor
Odor Threshold: Not available

Fire and Explosion Hazard Data

Flash Point (O°C): Not applicable.
Flammability: Not flammable under conditions of use.

Flammable Limits

Lower Explosive Limit: Not applicable
Upper Explosive Limit: Not applicable

Auto-ignition Temperature: Not applicable

Explosion Data
Like most organic materials in powder form, the toner can 
form explosive mixtures when dispersed in air.

Sensitivity to Mechanical Impact: Not available
Sensitivity to Static Discharge: Not available.

Extinguishing Media: Water spray, foam, dry chemicals.
Special Fire Fighting Procedures: In case of fire, use 

extinguishing media. When mounted in the printer, treat as 
an electrical fire.

Hazardous Combustion Products: Not applicable

Toxicological Properties

Routes of Entry: Inhalation, Ingestion, Eyes, Skin
Effects of Acute Exposure (based on toxicity data for 

similar materials and ingredients):

Swallowed LD50 (rat): > 5.0 g/kg
Skin LD50 (rabbit): > 5.0 g/kg
Inhaled LC50 (rat): > 5 mg/L/4hr

Effects of Chronic Exposure (based on toxicity data for 

similar materials and ingredients): The results obtained 
from a sponsored, Chronic Toner Inhalation Study, 
demonstrated no lung change in rats for the lowest (1 mg/
m3) exposure level (i.e. the level most relevant to 
potential human exposure).

A very slight degree of fibrosis was noted in 25% of the 

animals at the middle (4 mg/m3) exposure level, while a 
slight degree of fibrosis was noted in all the animals at the 
highest (16 mg/m3) exposure level.

These findings are attributed to "lung overloading," a 

generic response to excessive amounts of any dust 
retained in the lungs for a prolonged period. This study 
was conducted using a special test toner to comply with 
EPA testing protocol. The test toner was ten times more 
respirable than commercially available Oki toner, and 
would not be functionally suitable for Oki equipment.

Exposure Limits, ACGIH TLV†:

Total: 10 mg/m3
Respirable: 3 mg/m3

Irritancy:  Not an irritant.†
Sensitization (skin, guinea pig):  Not a sensitizer.†

Carcinogenicity: Not classified as “Carcinogens” 

IARC: Refer to IARC Monographs on the Evaluation 
Carcinogenic Risks to Humans (WHO International 
Agency for Research on cancer).
NTP: Refer to National Toxicology Program (NTP) 
Report on Carcinogens (NTP).
OSHA: Not available.

_____________________________
†Based on toxicity data for similar materials and 
ingredients.

Summary of Contents for MPS730b

Page 1: ...guridad de los Materiales MSDS 25 English Safety Information 2 Regulatory Information 6 Material Safety Data Sheet MSDS 7 America Latina otro Latin America Other Espa ol Informaci n de Seguridad 17 In...

Page 2: ...fits into a grounded outlet If the plug does not fit the outlet may be an older non grounded type Contact an electrician to have the outlet replaced Do not use an adapter to defeat the grounding Inst...

Page 3: ...and electric shock do not use the power cable supplied with this product for any other electrical equipment If you do not connect the power cord or any other cables only as directed in the User s Gui...

Page 4: ...Warranty contact your local Oki Data authorized service center Oki Data at 1 800 654 3282 1 800 OKI DATA or www okiprintingsolutions com Once the one 1 year on site period is over the original purcha...

Page 5: ...nute Oki information specifically for your product including Product news Manuals Drivers and utilities Material Safety Data Sheets Searchable knowledge base and much more Just take a few minutes sett...

Page 6: ...Laurel NJ 08054 4620 1 800 654 3282 1 800 OKI DATA FCC Radio Frequency Interference Statement WARNING This equipment has been tested and found to comply with the limits for a Class B digital device p...

Page 7: ...o ignition Temperature Not applicable Explosion Data Like most organic materials in powder form the toner can form explosive mixtures when dispersed in air Sensitivity to Mechanical Impact Not availab...

Page 8: ...ties Remove sources of ignition Keep unnecessary and unprotected personnel away from area Wear protective gear respirator rubber gloves goggles After removing the bulk of the spill wipe up remainder w...

Page 9: ...s de mise la terre Elle ne s adapte qu une prise murale reli e la terre Si vous ne pouvez pas la brancher votre prise de courant est sans doute un ancien mod le sans prise de terre Communiquez avec un...

Page 10: ...ctrocution Pour viter tout risque d incendie et d lectrocution n utilisez pas le c ble fourni ici avec un autre quipement lectrique Si vous ne connectez pas le cordon d alimentation ou d autres c bles...

Page 11: ...de la pr sente garantie Pour formuler une demande de r paration ou une r clamation en vertu de la pr sente Garantie limit e communiquez avec le centre de r paration agr Oki Data de votre voisinage ou...

Page 12: ...composez le 1 905 238 4275 La pr sente Garantie limit e s applique ce Produit Oki Data Toutefois la proc dure suivre pour obtenir de l assistance peut varier l ext rieur des tats Unis continentaux Ve...

Page 13: ...pilotes et utilitaires fiche de donn es de sant s curit base de connaissances pouvant tre interrog e et plus encore Il suffit de prendre quelques minutes pour le configurer pour consulter votre Centre...

Page 14: ...l 3 Partie responsable Oki Data Americas Inc 2000 Bishops Gate Boulevard Mt Laurel NJ 08054 4620 1 800 654 3282 1 800 OKI DATA D claration sur le brouillage radio lectrique de la FCC AVERTISSEMENT l i...

Page 15: ...inf rieure d explosion Sans objet Limite sup rieure d explosion Sans objet Temp rature d auto inflammation Sans objet Explosions Comme la plupart des mat riaux organiques sous forme poudreuse le toner...

Page 16: ...ez toute source d inflammation 2Ramassage par balayage ou l aide d un chiffon humide eau froide D versements importants comme dans les installations de traitement 1 loignez toute source d inflammation...

Page 17: ...n enchufe con conexi n a tierra de tres contactos Solamente se puede enchufar en un tomacorriente con conexi n a tierra Si no lo puede enchufar es posible que tenga un tomacorriente antiguo sin conexi...

Page 18: ...o para este producto puede producir incendios o descargas el ctricas Para evitar el riesgo de que se produzcan incendios y descargas el ctricas no utilice el cable de alimentaci n que se suministra co...

Page 19: ...es y utilidades Hojas de Informaci n sobre seguridad de los materiales MSDS B squeda en bases de datos y mucho m s Para crear su centro personal solo tiene que emplear unos pocos minutos y en el futur...

Page 20: ...la fecha de recepci n del Producto en el lugar en que pueda hacerse efectiva esta garant a 3 Se podr n adquirir refacciones en el lugar se alado en el punto No 1 anterior Esta Garant a Limitada no apl...

Page 21: ...SPECTIVO DE GARANT A DESCRITO ANTERIORMENTE BAJO NINGUNA CIRCUNSTANCIA OKI DATA O CUALQUIERA DE SUS FILIALES SER RESPONSABLE ANTE UN COMPRADOR O CUALQUIER OTRA PERSONA POR DA OS ESPECIALES COLATERALES...

Page 22: ...Responsable Oki Data Americas Inc 2000 Bishops Gate Boulevard Mt Laurel NJ 08054 4620 1 800 654 3282 1 800 OKI DATA Declaraci n de la FCC en relaci n a la Interferencia de Radiofrecuencias Advertencia...

Page 23: ...enta un riesgo de peligro o da os f sicos Si los servicios bajo garant a no pueden ser realizados o completados debido a cualquiera de las razones anteriores la opci n de Servicio en Sitio queda anula...

Page 24: ...di el producto o comunic ndose con Oki Data directamente al 1 800 654 3282 1 800 OKI DATA o www okiprintingsolutions com o comunic ndose con uno de los lugares de asistencia t cnica de la lista siguie...

Page 25: ...u uso L mites de inflamabilidad L mite de explosi n inferior No procede L mite de explosi n superior No procede Temperatura de auto ignici n No procede Informaci n sobre explosi n Como la mayor a de l...

Page 26: ...icas de higiene Ninguna Limpieza de Derrames Derrames menores Eliminar las fuentes de ignici n Barrer o recolectar con un pa o mojado en agua fr a Derrames mayores como en instalaciones de procesamien...

Page 27: ...800 11 5577 Demais cidades ou visite WWW OKIPRINTINGSOLUTIONS COM A impressora tem um plugue de 3 pinos aterrado como recurso de seguran a Ele encaixar somente em uma tomada aterrada Se n o for poss v...

Page 28: ...Para evitar o risco de inc ndio e choque el trico n o use o cabo de alimenta o fornecido com este produto em qualquer outro equipamento el trico Se o cabo de alimenta o ou qualquer outro cabo n o for...

Page 29: ...ica Autorizados Oki Data do Brasil Ficar sob responsabilidade do Adquirente o transporte do Produto at um dos Centros de Assist ncia T cnica Autorizados Oki Data do Brasil devendo o Adquirente arcar c...

Page 30: ...terfer ncia recebida incluindo interfer ncias que possam causar opera o indesej vel 3 Parte respons vel Oki Data Americas Inc 2000 Bishops Gate Boulevard Mt Laurel NJ 08054 4620 1 800 654 3282 1 800 O...

Page 31: ...isturas explosivas quando disperso no ar Sensibilidade a impacto mec nico N o dispon vel Sensibilidade descarga est tica N o dispon vel Meios de extin o Esguicho d gua espuma p qu mico Procedimentos e...

Page 32: ...remover a maior parte do derramamento limpar o restante com um pano mido usar gua fria Colocar o material descartado em um recipiente fechado Descarte de material usado Seguir as regulamenta es federa...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...59409001 OKI Oki Electric Industry Company Ltd ENERGY STAR United States Environmental Protection Agency 2010 Oki Data Americas Inc...

Reviews: