ML7065-033 User’s Manual
Chapter 7 Commands
32
7.3.27 MLME-COMM-STATUS.indication
Function: Posts the communication results
Command symbol: 0x5A
Access: MAC
No. Parameter
Type
Value
range
Description
1
PANId
U16
0x0000 – 0xFFFF
16-bit PANidentifier
2
SrcAddrMode
U8
0x00 – 0x03
Addressing mode of the communication
source
0x00: No address
0x01: Reserved
0x02: 16-bit short address
0x03: 64-bit extended address
3 SrcAddr
*
(Depends on the value of
SrcAddrMode)
Device address of the communication
source
4
DstAddrMode
U8
0x00 – 0x03
Addressing mode of the communication
destination
0x00: No address
0x01: Reserved
0x02: 16-bit short address
0x03: 64-bit extended address
5 DstAddr
*
(Depends on the value of
DstAddrMode)
Device address of the communication
destination
6 Status
U8
SUCCESS,
TRANSACTION_OVERFLOW,
TRANSACTION_EXPIRED,
CHANNEL_ACCESS_FAILURE,
NO_ACK,
UNAVAILABLE_KEY,
FRAME_TOO_LONG,
FAILED_SECURITY_CHECK,
INVALID_PARAMETER
Status indicating the communication
results
7.3.28 MLME-SET.request
Function: Sets PIB attribute information
Command symbol: 0x5B
Access: MAC
No. Parameter
Type
Value
range
Description
1
PIBAttribute
U8
(*)
Identifier of the PIB attribute to be set
2
PIBAttributeValue
*
(*)
Value of the PIB attribute to be set
* For details of PIBAttribute, refer to Section 7.4, “MAC PIB Attribute Specifications.”
[Oki unique attribute]
Attribute Identifier
Type
Description
aExtendedAddress
0x6F
U8
64-bit IEEE address assigned to the device