![Oki ML420 Series Maintenance Manual Download Page 19](http://html2.mh-extra.com/html/oki/ml420-series/ml420-series_maintenance-manual_3760493019.webp)
42113901TH01 Rev.3
19 /
Oki Data CONFIDENTIAL
9)
Signal Level
• Input / Output Level
Parameter
Input Levels :
High (driven)
High (floating)
Low
Output Levels :
Low
High (driven)
Output Signal Crossover Voltage
Symbol
V
IH
V
IHZ
V
IL
OL
OH
V
CRS
Min.
2.0
2.7
0.0
2.8
1.3
Max.
3.6
0.8
0.3
3.6
2.0
Units
V
V
V
V
V
V