45850101TH Rev.1
3-8
Oki Data CONFIDENTIAL
3. MAINTENANCE MENUS
Item1
Item2
Item3
Item4
Item5
Value
Default
value
ODA
Default
value
OEL
Default
value
JP
Notes
Password
Scanner
Maintenance
Mechanical
Test
ADF Test
Simplex/
Duplex
Simplex
Duplex
Conduct mechanical testing (without reading an image).
ADF : Test moving original document (stops when set document has
been moved)
May choose from single- or double-sided feeding.
FBS : CIS moving test (stops after designated number of operations)
Use fastest read speed (30 cpm).
On the panel, indicate current number of executions using the
message "Test no. xxx underway."
Speed
Color 300 x 600dpi
Color 600 x 600dpi
Mono 600 x 600dpi
Execute
--Results--
Test no. xxx underway
FBS Test
Speed
Color 300 x 600dpi
Color 600 x 600dpi
Mono 600 x 600dpi
Conduct mechanical testing (without reading an image).
ADF : Test moving original document (stops when set document has
been moved)
May choose from single- or double-sided feeding.
FBS : CIS moving test (stops after designated number of operations)
Use fastest read speed (40 cpm).
On the panel, indicate current number of executions using the
message "Test no. xxx underway."
Times
0~100,000
Execute
--results--
Test no. xxx underway
Sensor
Test
Examples of this display are
shown below:
①
MEDIA H/L
②
REGIST
H/L
③
SCAN H/L
④
REVERSE H/L
⑤
ADF CVR H/L
⑥
FB HP H/L
⑦
FB SIZE1
H/L
⑧
FB SIZE2
H/L
⑨
ADF OPEN1 H/L
⑩
ADF OPEN2 H/L
⑪
ADF SIZE1 H/L
⑫
ADF SIZE2 H/L
Display sensor status (H/L) in real time. Change the content of the
display as needed when the sensor status displayed changes.
①
MEDIA H/L
②
REGIST
H/L
③
SCAN H/L
④
REVERSE H/L
⑤
ADF CVR H/L
⑥
FB HP H/L
⑦
FB SIZE1
H/L
⑧
FB SIZE2
H/L
⑨
ADF OPEN1 H/L
⑩
ADF OPEN2 H/L
⑪
ADF SIZE1 H/L
⑫
ADF SIZE2 H/L