Chapter 6 Parts Replacement (Disassembly/Reassembly)
6-44
6.6
Disassembling and Reassembling the POWER BOX
<How to open the POWER BOX>
1.
Be sure to disconnect the power cord
from the outlet before starting the
procedure.
2.
Of the six screws securing the
POWER-BOX-COVER-F, loosen the
three screws on the upper side.
3.
Out of the six screws, remove the three
screws securing the
POWER-BOX-COVER-F on the lower
side, and then remove the
POWER-BOX-COVER-F.
4.
Remove the four screws securing the
POWER-BOX-CASE-MW-BOTTOM (two
screws on each side), and pull the
POWER-BOX-CASE-MW-BOTTOM
toward you approximately 10 cm.
5.
Disconnect the four connectors.
POWER-BOX-CASE-MW-BOTTOM
Loosen the three screws
Remove the three screws
POWER-BOX-COVER-F