2-54 Color Calibration
ES3640e MFP Color Guide - 54
Calibrating the Fiery with the ED-100
You can use ColorWise Pro Tools in conjunction with the ED-100 to
calibrate the Fiery.
To calibrate the Fiery using the ED-100
1. Start Calibrator.
For instructions on starting Calibrator, see
.
2. Choose EFI Densitometer ED-100 as the measurement method.
3. In the Check Print Settings pane, choose the desired calibration
set.
Choose the appropriate calibration set for the type of media you
will use most often.
Note:
For this calibration to take effect, the calibration set must be
associated with one or more output profiles. There is no need to
make any new associations for the default calibration set, since it
is already associated with the default output profile.
4. In the Generate Measurement Page pane, click Print.
The Print Options dialog box appears.
5. Choose the appropriate options and click Print.
For Page Type, choose 21 Sorted
Patches. Sorted patches are printed
on the page in the order of their
hue and saturation levels.
Paper Size is automatically set to
LTR/A4 for 21 Patches.
For Input Tray, specify the paper
source for printing the
measurement page.
6. Retrieve the measurement page
from the printer.