Colour Calibration
12.
After you hear a beep, slide the ES-1000 at a slow but consistent pace across
the strip.
13.
Release the button when all the patches in the strip have been measured, and you
have reached the white space at the end of the strip.
When a strip is measured successfully, the cross hair moves to the next colour.
14.
Repeat
through
until all the strips have been measured.
N
OTE
:
You must take the measurements in the order outlined in the Status field.
15.
When all the patches have been read successfully, click Accept.
16.
Click Apply in the Calibrator window to implement the new calibration measurement.
17.
Click OK in the Information dialog box.
This completes the Fiery calibration process.
Using the EFI Densitometer ED-100
The EFI Densitometer ED-100 is a hand-held instrument that measures the density of
printed ink and toner. Like the DTP32, the ED-100 is a reflection
densitometer
that
you can use to calibrate the Fiery.
Setting up the ED-100
To use the ED-100 for calibration purposes, you must first set it up for use with your
computer. For complete instructions on setting up the ED-100, see the documentation
that is included with the instrument.
The following illustration shows the components of the ED-100.
Indicator light
Sample aperture
(underneath)
Measure button